4.2 Article

Experiment and modelling of the strain-rate-dependent response during in vitro degradation of PLA fibres

Journal

SN APPLIED SCIENCES
Volume 2, Issue 2, Pages -

Publisher

SPRINGER INTERNATIONAL PUBLISHING AG
DOI: 10.1007/s42452-020-1964-4

Keywords

Hydrolytic degradation; Mechanical behaviour evolution; PLA fibres; Nonlinear viscoelasticity; Tissue engineering

Funding

  1. University of Santiago de Compostela (Spain)
  2. Norte Portugal Regional Operational Programme (NORTE 2020), under PORTUGAL 2020 Partnership Agreement, through the European Regional Development Fund (ERDF) [NORTE-01-0145-FEDER-000005]
  3. European Regional Development Fund (ERDF) through COMPETE 2020 Programa Operacional Competitividade e Internacionalizacao (POCI) [POCI-01-0145FEDER-006939, UID/EQU/00511/2013]
  4. national funds through FCT-Fundacao para a Ciencia e a Tecnologia

Ask authors/readers for more resources

Polylactic acid (PLA) fibres present, in their pristine state, a strain-rate-dependent behaviour. Their mechanical properties evolve during in vitro biodegradation. Tensile tests of PLA fibres are performed at five different strain rates 0.0001, 0.001, 0.01, 0.05 and 0.1/s and at seven degradation stages, 0, 20, 40, 60, 90, 120 and 150 days in a phosphate buffer solution at constant temperature at 37 degrees C. The mechanical response is modelled using a modified three-element standard solid model proposed for polymers under finite deformations range. Observations on experimental data lead to the conclusion that the viscous parameters eta(1) and eta(2) are strain rate dependent, and they vary from 10,762/3202 (N/m s) at the lowest strain rate of 0.0001/s, and 12.2/9.1 (N/m s) at the highest strain rate of 0.1/s for eta(1) and eta(2), respectively, thus, depicting the shear-thinning phenomena with the increase in strain rate. Whereas stiffness parameters C-1 and C-2 are degradation dependent, they vary from 21.6/13.7 (N/m) for undegraded PLA fibres and 9.7/5.4 (N/m) for 150 days degraded PLA fibres for C-1 and C-2, respectively. Decay of stiffness parameters during biodegradation follows an exponential law. The model will be useful to design and develop new fibrous structures for ligament augmentation devices. It could contribute to develop better devices with improved mechanical performance helping those patients in need to repair the ligament tissue.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available