4.6 Article

Remote Measurement of Human Vital Signs Based on Joint-Range Adaptive EEMD

Journal

IEEE ACCESS
Volume 8, Issue -, Pages 68514-68524

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/ACCESS.2020.2985286

Keywords

Non-contact vital sign detection; ensemble empirical mode decomposition (EEMD); frequency-modulated continuous-wave (FMCW); multiple measurement vectors (MMV); mm-wave radar

Funding

  1. National Natural Science Foundation of China [61871224, 81601568]
  2. Key Research and Development Plan of Jiangsu Province [BE2018729]
  3. Fundamental Research Funds for the Central Universities [30917011316]

Ask authors/readers for more resources

Remote techniques for measuring human vital signs have attracted great interests due to the benefits shown in medical monitoring and military applications. Compared with continuous-wave Doppler radar, frequency-modulated continuous-wave (FMCW) radar which can discriminate vital signs from different distances, shows potential for reducing the interferences from other targets and the environment. However, in the state-of-the-art algorithms, only one chirp per frame is utilized for FMCW-based vital sign monitoring. Moreover, the vital signal is extracted from only one range bin of the fast Fourier transform. Which does not make full utilization of the long system idle time, and loses the power distributed on other range bins. By exploiting the relationship between respiration and heartbeat vibrations, an adaptive identification embedded ensemble empirical mode decomposition (EEMD) method for joint-range spectral estimation is proposed to measure the heart rate. First, A multi-chirp processing is presented for a 2-dimensional phase accumulation. Then the phase signals from a sequence of range bins are decomposed with a fast adaptive identification process. Finally, with the identified heartbeat components, we solve a multiple measurement vectors problem to estimate the heart rate. Experimental results showed that, at the detection range from 1 m & x007E; 2.5 m, the proposed method can robustly distinguish the heartbeat from respiration and its harmonics and accurately estimate the heart rate with a root mean square error less than 6 bpm.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available