4.6 Article

Infective Endocarditis Risk After Percutaneous Pulmonary Valve Implantation With the Melody and Sapien Valves

Journal

JACC-CARDIOVASCULAR INTERVENTIONS
Volume 10, Issue 5, Pages 510-517

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jcin.2016.12.012

Keywords

cardiac valve; congenital heart defects; infective endocarditis; Melody valve; percutaneous pulmonary valve implantation; Sapien valve

Funding

  1. French Health Ministry

Ask authors/readers for more resources

OBJECTIVES This study compared the risk of infective endocarditis (IE) after percutaneous pulmonary valve implantation (PPVI) with the Sapien and Melody valves. BACKGROUND The incidence of IE after PPVI is estimated at 3% per year with the Melody valve. The Sapien valve is a more recently marketed valve used for PPVI. METHODS We retrospectively included consecutive patients who underwent PPVI at a single center between 2008 and 2016. IE was diagnosed using the modified DUKE criteria. RESULTS PPVI was performed in 79 patients (Melody valve, 40.5%; Sapien valve, 59.5%). Median age was 24.9 years (range 18.1 to 34.6). IE occurred in 8 patients (10.1%) at a median of 1.8 years (minimum: 1.0; maximum: 5.6) after surgery. Causative organisms were methicillin-sensitive Staphylococcus aureus (n = 3), Staphylococcus epidermidis (n = 1), Streptococcus mitis (n = 1), Aerococcus viridans (n = 1), Corynebacterium striatum (n = 1), and Haemophilus influenzae (n = 1). All 8 cases occurred after Melody PPVI (25.0% vs. 0.0%). The incidence of IE was 5.7% (95% confidence interval: 2.9% to 11.4%) per person-year after Melody PPVI. The Kaplan-Meier cumulative incidence of IE with Melody PPVI was 24.0% (95% confidence interval: 12.2% to 43.9%) after 4 years and 30.1% (95% confidence interval: 15.8% to 52.5%) after 6 years, compared with 0.0% with the Sapien PPVI after 4 years (p < 0.04 by log-rank test). There was a trend toward a higher incidence of IE in the first 20 patients with Melody PPVI (who received prophylactic antibiotics during the procedure only) and in patients who had percutaneous interventions, dental care, or noncardiac surgery after PPVI. CONCLUSIONS IE after PPVI may be less common with the Sapien compared with the Melody valve. (C) 2017 by the American College of Cardiology Foundation.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available