Visualization of refrigerant flow at the capillary tube inlet of a high-efficiency household refrigerator

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.ijrefrig.2016.09.019

Keywords

Household refrigerator; Capillary tube; Subcooling; Flow visualization

Funding

  1. Santiago Grisolia programme - Generalitat Valenciana [GRISOLIA/2015/021]

Ask authors/readers for more resources

The subcooled condition at the condenser outlet ensures complete condensation, which is necessary in vapor compression systems to increase the cooling capacity and ensure the liquid conditions at the expansion device inlet. However, in household refrigerators, recent works indicate the presence of two-phase flow at the capillary tube inlet. These systems behave quite differently from other refrigeration systems due to the extremely low capacity In the present work, a test bench was built to visualize the refrigerant flow at the condenser outlet and at the capillary tube inlet of a commercial household refrigerator. A transparent tube replaced the end of the condenser and three transparent filters were installed with different orientations. Different positions of the capillary tube within the filters were also tested. Despite measuring a certain subcooling, all the reported visualizations showed that the capillary tube was steadily drawing in two-phase flow. (C) 2016 Elsevier Ltd and IIR. All rights reserved.