4.7 Article Proceedings Paper

Towards autonomous lateral flow assays: Paper-based microfluidic fuel cell inside an HIV-test using a blood sample as fuel

Journal

INTERNATIONAL JOURNAL OF HYDROGEN ENERGY
Volume 42, Issue 46, Pages 27979-27986

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijhydene.2017.07.079

Keywords

Lateral flow assay; Glucose oxidase; Paper-based microfluidic fuel cell; Blood sample as fuel

Funding

  1. CONACYT [611]
  2. Laboratorio Nacional de Micro y Nanofluidica [2017280485]
  3. Fondo de Fortalecimiento a la Investigacidn UAQ [FIN201618]

Ask authors/readers for more resources

This work presents the integration of a paper-based microfluidic fuel cell inside a lateral flow assay-human immunodeficiency virus (HIV) test. To modify the HIV test, a bioanode that oxidizes the glucose present in a serum or blood sample and a cathode that reduces the oxygen delivered from air were stacked on the bottom and top, respectively, of a paper strip test. A mixture of glucose oxidase enzyme, Nafion (R), glutaraldehyde, deionized water and tetrabutylammonium bromide were deposited on a methylene blue electro-polymerized Toray (R) paper and used as the bioanode. Meanwhile, Pt/C (Vulcan XC-72) on Toray (R) paper was used as an air-breathing cathode. The GOx enzyme anchored on the carbon-based surface was examined by scanning electron microscopy. The electro-chemical response of the bioanode array demonstrated the oxidation of 0.1 M glucose, leading to a current density increase due to FAD(+)/FADH reactions. The above procedure was corroborated through scanning electrochemical microscopy, which showed an increase in the current (400 pA) in the presence of glucose on the bioanode. The paper-based microfluidic fuel cell performance showed power densities of 0.16 and 0.12 mW cm(-2) using human serum and blood samples, respectively. Furthermore, the stability of the device was measured in terms of the recovery after obtaining four polarization curves that lasted 30 min, after which the sample dried out. This work represents a great advancement in the integration of a paper-based microfluidic fuel cell towards autonomous lateral flow assays. (C) 2017 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available