4.5 Article

Influence of continuous rotation or reciprocation of Optimum Torque Reverse motion on cyclic fatigue resistance of nickel-titanium rotary instruments

Journal

INTERNATIONAL ENDODONTIC JOURNAL
Volume 51, Issue 5, Pages 522-528

Publisher

WILEY
DOI: 10.1111/iej.12769

Keywords

continuous rotation; cyclic fatigue; nickel-titanium files; Optimum Torque Reverse motion; reciprocation

Ask authors/readers for more resources

AimTo evaluate the resistance to cyclic fatigue of ProTaper Next (PTN; Dentsply Sirona, Ballaigues, Switzerland), Revo-S (Micro-Mega, Besancon, France), Mtwo (Sweden & Martina, Padova, Italy), Twisted Files (TF, SybronEndo, Orange, CA, USA) and EndoWave (J Morita Corporation, Osaka, Japan) used in continuous rotation or in reciprocation of Optimum Torque Reverse motion (OTR). MethodologyA total of 120 nickel-titanium files were tested. Twenty-four instruments for each brand were divided into two groups (n=12) on the basis of the motion tested: continuous rotation (Group 1) or reciprocation of OTR motion (Group 2). Resistance to cyclic fatigue was determined by recording time to fracture (TtF) in a stainless steel artificial canal with a 60 degrees angle of curvature and 5mm radius of curvature. The TtF data were analysed by using two-way analysis of variance (anova) and Bonferroni's post hoc tests at 0.05. ResultsMtwo and TF had significantly higher TtF when compared with all other instruments, both in continuous rotation and in reciprocation of OTR motion (P<0.0001 and P<0.05, respectively). No difference was observed between Mtwo and TF (P>0.05), in both motions. PTN was associated with higher cyclic fatigue resistance than Revo-S and EndoWave, both in continuous rotation and in reciprocation of OTR motions (P<0.0001). No difference was observed between Revo-S and EndoWave, in both motions (P>0.05). Reciprocating OTR motion improved TtF of all instruments (P<0.0001). ConclusionsReciprocation of OTR motion improved significantly cyclic fatigue resistance of all instruments tested compared with continuous rotation. Mtwo and TF had significantly higher cyclic fatigue than the other instruments, in both continuous rotation and reciprocation of OTR motion.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available