4.7 Article

Uniform manganese-loaded titanium dioxide nanotube arrays for accurate detection of trace Cd2+ in water, soil and tea: Enhanced stability and sensitivity

Journal

CHEMICAL ENGINEERING JOURNAL
Volume 400, Issue -, Pages -

Publisher

ELSEVIER SCIENCE SA
DOI: 10.1016/j.cej.2020.125972

Keywords

Self-organizing and ordered Mn-TiO2 NTAs; ECP-LIBS; MATLAB; Simulation; High stability and sensitivity

Funding

  1. National Natural Science Foundation of China [21735005, 21802145]
  2. Natural Science Foundation of Anhui Province [2008085QB79]
  3. postdoctoral innovation talents supporting project [BX20180311]
  4. China Postdoctoral Science Foundation [2019 M652220]
  5. Science and Technology Major Project of Anhui Province [17030801033]
  6. Key Program of 13th five-year plan, CASHIPS
  7. Science and Technology Research Project of Anhui Province [1704c0402195]
  8. One Hundred Person Project of the Chinese Academy of Sciences, China

Ask authors/readers for more resources

The poor stability of the signal obtained on nonuniform substrate, which results from the obvious difference in the size of ablation spots, the uneven distribution of enriched analytes, and the severe matrix effect, seriously affecting the practical application of electrochemical preconcentration supported laser-induced breakdown spectroscopy (ECP-LIBS). Here, self-organizing and ordered manganese loaded titanium dioxide nanotube arrays (Mn-TiO2 NTAs) on a titanium foil was employed as the working electrode to overcome the problem. The MnTiO2 NTAs were of equal height, hollow-structured and evenly arranged on the electrode, leading to uniform and shallow ablation spots after Gaussian laser irradiation (proven by MATLAB simulation), which reduced the matrix effect. As a result, a high sensitivity of 13347.7 counts mu M-1 and low LOD of 0.01 mu M for Cd2+ were achieved. Most importantly, the self-organizing and ordered Mn-TiO2 NTAs electrode exhibited outstanding stability and reproducibility (relative standard deviation, RSD, was less than 5%), while the Mn-TiO2 electrode modified through the drip coating method showed poor stability (RSD was greater than 20%). The proposed method perfectly achieved the anti-interference and accurate detection of Cd2+ in water, soil and tea.