4.7 Article

Development of Uric Acid Sensor Using Copper Oxide and Silver Nanoparticles Immobilized SMSMS Fiber Structure-Based Probe

Journal

IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT
Volume 69, Issue 11, Pages 9097-9104

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TIM.2020.2998876

Keywords

Optical fiber sensors; Optical fibers; Probes; Optical fiber communication; Copper oxide nanoparticles (CuO-NPs); in-line Mach-Zehnder interferometer (MZI); multimode fiber; silver nanoparticles (AgNPs); single-mode fiber; uric acid (UA) sensor; uricase

Funding

  1. Belt and Road Special Project
  2. Double-Hundred Talent Plan of Shandong Province
  3. National Key Research & Development Program of China [2016YFB0402105]
  4. Liaocheng University, China [31805180301, 31805180326]
  5. Science and Engineering Research Board, India [TAR/2018/000051]

Ask authors/readers for more resources

Fabrication and experimental validation of a newly developed copper oxide nanoparticles (CuO-NPs) and silver nanoparticles (AgNPs) immobilized SM-MM-SM-MM-SM (SMSMS) in-line Mach-Zehnder interferometer (MZI) fiber structure-based sensor using localized surface plasmon resonance (LSPR) technique are reported in this article. The AgNPs and CuO-NPs are used to improve the biocompatibility and sensitivity of the sensor. The nanoparticles (NPs) and immobilized probe were characterized by UV-Vis spectrophotometer, HR-TEM, SEM, and EDX, revealing superior performance over the existing uric acid (UA) sensors. The proposed optimized structure-based optical fiber sensors (OFSs) exhibit excellent specificity, sensitivity, and limit of detection (LoD) for the detection of UA. Moreover, the developed sensor exhibits linear profile over a very wide range: 1) 10 mu M-1 mM for detection over UA presents in serum, while the normal range of UA in serum is 100-400 mu M and 2) 0.4-10 mM for detection over UA presents in urine, while the normal range of UA in urine is 1.5-4.4 mM. In addition, the developed sensor has a distinguished advantage, such as multicompatibility over the detection of UA presents in both serum and urine along with its high selectivity, reusability, reproducibility, and lowest LoD. The proposed AgNPs and CuO-NPs immobilized and the uricase functionalized SMSMS structure-based LSPR sensor has better compatibility and are potent candidates for medical applications.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available