4.7 Article

Enhanced O2-• and HO• via in situ generating H2O2 at activated graphite felt cathode for efficient photocatalytic fuel cell

Journal

CHEMICAL ENGINEERING JOURNAL
Volume 399, Issue -, Pages -

Publisher

ELSEVIER SCIENCE SA
DOI: 10.1016/j.cej.2020.125839

Keywords

Graphite felt cathode; H2O2 production; Oxygen-containing group; Radical reaction; Energy recovery; Photocatalytic fuel cell

Funding

  1. National Natural Science Foundation of China [21875139, 21776177]
  2. National Key Research and Development Program of China [2018YFE0122300]
  3. Shanghai International Science and Technology Cooperation Fund Project [18520744900]
  4. AEMD of Shanghai Jiao Tong University

Ask authors/readers for more resources

The use of a photocatalytic fuel cell (PFC) in wastewater treatment is an intensively researched topic because the device integrates organic pollutant degradation and chemical energy recovery. Herein, we proposed a strategy to enhance PFC performance by increasing the concentrations of hydroxyl radical (HO center dot) and superoxide radical (O-2(-center dot)) produced from H2O2 generated in situ using an activated graphite felt (GF) cathode. This cathode was prepared by H2SO4 treatment to introduce oxygen-containing functional groups on its surface that would serve as surface-active sites and facilitate the two-electron pathway of H2O2 production. Remarkably, the peak current density of the activated GF cathode (-1.25 mA/cm(2)) was more than thrice that of the original GF cathode (-0.40 mA/cm(2)), and its Faradaic efficiency significantly improved from 20.01% to 74.09%. The PFC equipped with the activated GF cathode harvested 2.69 times the maximum power density (JVmax) and 5.15 times the degradation rate of the traditional Pt black-PFC system. This was because the O-2(center dot-) and HO center dot concentrations, respectively, were 2.87 (23.98 x 10(-5) M) and 2.48 times (13.00 x 10(-4) M) as high as those in the Pt black-PFC system. These results were attributed to the high concentration of H2O2 generated in situ at the activated GF cathode, which was 25.13 times (0.402 mM) as high as that generated at the Pt black cathode. Thus, the proposed PFC system demonstrates the feasibility of improving organic pollutant degradation and energy recovery by enhancing H2O2 production.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available