4.7 Article

Line Detection as an Inverse Problem: Application to Lung Ultrasound Imaging

Journal

IEEE TRANSACTIONS ON MEDICAL IMAGING
Volume 36, Issue 10, Pages 2045-2056

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TMI.2017.2715880

Keywords

Line detection; deconvolution; image restoration; ultrasound; inverse problem; ADMM; sparsity regularisation

Funding

  1. Wellcome Trust Institutional Strategic Support Fund, Elizabeth Blackwell Institute, University of Bristol
  2. EPSRC Platform Grant, Vision for the Future [EP/M000885/1]
  3. EPSRC [EP/M000885/1] Funding Source: UKRI
  4. Engineering and Physical Sciences Research Council [EP/M000885/1] Funding Source: researchfish

Ask authors/readers for more resources

This paper presents a novel method for line restoration in speckle images. We address this as a sparse estimation problem using both convex and non-convex optimization techniques based on the Radon transform and sparsity regularization. This breaks into subproblems, which are solved using the alternating direction method of multipliers, thereby achieving line detection and deconvolution simultaneously. We include an additional deblurring step in the Radon domain via a total variation blind deconvolution to enhance line visualization and to improve line recognition. We evaluate our approach on a real clinical application: the identification of B-lines in lung ultrasound images. Thus, an automatic B-line identification method is proposed, using a simple local maxima technique in the Radon transform domain, associated with known clinical definitions of line artefacts. Using all initially detected lines as a starting point, our approach then differentiates between B-lines and other lines of no clinical significance, including Z-lines and A-lines. We evaluated our techniques using as ground truth lines identified visually by clinical experts. The proposed approach achieves the best B-line detection performance as measured by the F score when a non-convex l(p) regularization is employed for both line detection and deconvolution. The F scores as well as the receiver operating characteristic (ROC) curves show that the proposed approach outperforms the state-of-the-art methods with improvements in B-line detection performance of 54%, 40%, and 33% for F-0.5, F-1, and F-2, respectively, and of 24% based on ROC curve evaluations.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available