4.8 Article

Detection of False-Data Injection Attacks in Cyber-Physical DC Microgrids

Journal

IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS
Volume 13, Issue 5, Pages 2693-2703

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TII.2017.2656905

Keywords

Cyber-physical systems (CPS); dc microgrid; distributed control; false-data injection attack (FDIA); hybrid automaton

Funding

  1. National Science Foundation [ECCS-1405173, CNS 1464311, SHF 1527398]
  2. Air Force Research Laboratory [FA8750-15-1-0105]
  3. Air Force Office of Scientific Research [FA9550-15-1-0258, FA9550-16-1-0246]
  4. US Office of the Naval Research [N00014-14-1-0718]
  5. Direct For Computer & Info Scie & Enginr
  6. Division Of Computer and Network Systems [1713253] Funding Source: National Science Foundation
  7. Division of Computing and Communication Foundations
  8. Direct For Computer & Info Scie & Enginr [1736323] Funding Source: National Science Foundation
  9. Div Of Electrical, Commun & Cyber Sys
  10. Directorate For Engineering [1405173] Funding Source: National Science Foundation

Ask authors/readers for more resources

Power electronics-intensive dc microgrids use increasingly complex software-based controllers and communication networks. They are evolving into cyber-physical systems (CPS) with sophisticated interactions between physical and computational processes, making them vulnerable to cyber attacks. This paper presents a framework to detect possible false-data injection attacks (FDIAs) in cyber-physical dc microgrids. The detection problem is formalized as identifying a change in sets of inferred candidate invariants. Invariants are microgrids properties that do not change over time. Both the physical plant and the software controller of CPS can be described as Simulink/Stateflow (SLSF) diagrams. The dynamic analysis infers the candidate invariants over the input/output variables of SLSF components. The reachability analysis generates the sets of reachable states (reach sets) for the CPS modeled as hybrid automata. The candidate invariants that contain the reach sets are called the actual invariants. The candidate invariants are then compared with the actual invariants, and any mismatch indicates the presence of FDIA. To evaluate the proposed methodology, the hybrid automaton of a dc microgrid, with a distributed cooperative control scheme, is presented. The reachability analysis is performed to obtain the reach sets and, hence, the actual invariants. Moreover, a prototype tool, HYbrid iNvariant GEneratoR, is extended to instrument SLSF models, obtain candidate invariants, and identify FDIA.