An Optimized Hybrid Fractional Order Controller for Frequency Regulation in Multi-Area Power Systems

Journal

IEEE ACCESS
Volume 8, Issue -, Pages 213899-213915

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/ACCESS.2020.3040620

Keywords

Power system stability; Frequency control; Optimization; Hybrid power systems; Process control; Mathematical model; Transfer functions; Fractional order controller; load frequency control; manta ray foraging optimization; multi-area power systems; renewable energy sources; superconducting energy storage systems

Funding

  1. Ministry of Education in Saudi Arabia [375213500]
  2. central laboratory at Jouf University
  3. SERC Chile [ANID/FONDAP15110019]
  4. AC3E [ANID/Basal/FB0008]

Ask authors/readers for more resources

Multi-area power systems inhere complicated nonlinear response, which results in degraded performance due to the insufficient damping. The main causes of the damping problems are the stochastic behavior of the renewable energy sources, loading conditions, and the variations of system parameters. The load frequency control (LFC) represents an essential element for controlling multi-area power systems. Therefore, the proper design of the controllers is mandatory for preserving reliable, stable and high-quality electrical power. The controller has to suppress the deviations of the area frequency in addition to the tie-line power. Therefore, this paper proposes a new frequency regulation method based on employing the hybrid fractional order controller for the LFC side in coordination with the fractional order proportional integral derivative (FOPID) controller for the superconducting energy storage system (SMES) side. The hybrid controller is designed based on combining the FOPID and the tilt integral derivative (TID) controllers. In addition, the controller parameters are optimized through a new application of the manta ray foraging optimization algorithm (MRFO) for determining the optimum parameters of the LFC system and the SMES controllers. The optimally-designed controllers have operated cooperatively and hence the deviations of the area frequency and tie-line power are efficiently suppressed. The robustness of the proposed controllers is investigated against the variation of the power system parameters in addition to the location and/or magnitude of random/step load disturbances.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available