4.6 Article

Muscle Activity Map Reconstruction from High Density Surface EMG Signals With Missing Channels Using Image Inpainting and Surface Reconstruction Methods

Journal

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING
Volume 64, Issue 7, Pages 1513-1523

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TBME.2016.2603463

Keywords

Electromyography; image inpainting; image quality assessment; muscle activity map

Funding

  1. University of Isfahan

Ask authors/readers for more resources

Objective: The aim of this study was to reconstruct low-quality High-density surface EMG (HDsEMG) signals, recorded with 2-D electrode arrays, using image inpainting and surface reconstruction methods. Methods: It is common that some fraction of the electrodes may provide low-quality signals. We used variety of image inpainting methods, based on partial differential equations (PDEs), and surface reconstruction methods to reconstruct the time-averaged or instantaneous muscle activity maps of those outlier channels. Two novel reconstruction algorithms were also proposed. HDsEMG signals were recorded from the biceps femoris and brachial biceps muscles during low-to-moderate-level isometric contractions, and some of the channels (5-25%) were randomly marked as outliers. The root-mean-square error (RMSE) between the original and reconstructed maps was then calculated. Results: Overall, the proposed Poisson and wave PDE outperformed the other methods (average RMSE 8.7 mu V-rms +/- 6.1 mu V-rms and 7.5 mu V-rms +/- 5.9 mu V-rms) for the time-averaged single-differential and monopolar map reconstruction, respectively. Biharmonic Spline, the discrete cosine transform, and the Poisson PDE outperformed the other methods for the instantaneous map reconstruction. The running time of the proposed Poisson and wave PDE methods, implemented using a Vectorization package, was 4.6 +/- 5.7 ms and 0.6 +/- 0.5 ms, respectively, for each signal epoch or time sample in each channel. Conclusion: The proposed reconstruction algorithms could be promising new tools for reconstructing muscle activity maps in real-time applications. Significance: Proper reconstruction methods could recover the information of low-quality recorded channels in HDsEMG signals.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available