4.3 Article

Development and parametric study of the convection-type stationary adiabatic demagnetization refrigerator (ADR) for hydrogen re-condensation

Journal

CRYOGENICS
Volume 71, Issue -, Pages 82-89

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.cryogenics.2015.06.006

Keywords

Stationary adiabatic demagnetization refrigerator (ADR); Convection-type heat switch; Continuous operation; Conduction-cooled high temperature superconducting (HTS) magnet; Current cycling operation

Funding

  1. Converging Research Center Program through the Ministry of Science, ICT and Future Planning, Korea [2014M3C1A8048836]
  2. National Research Foundation of Korea [2014M3C1A8048836] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

Ask authors/readers for more resources

The adiabatic demagnetization refrigerator (ADR) system in this paper is composed of a conduction-cooled current cycling high-temperature superconducting (HTS) magnet system, a magnetic bed assembly, its heat exchange parts and an auxiliary precooling stage (a commercial GM cryocooler and a liquid nitrogen vessel). The whole magnetic refrigeration system including the conduction-cooled HTS magnet is cooled by the precooling stage to absorb the rejection heat of the ADR cycle. The packed bed type magnetic bed consists of tiny irregular powders of Dy0.9Gd0.1Ni2 enclosed in a thin walled stainless steel container (22.2 mm in O.D., 0.3 mm in thickness and 40.0 mm in height). The precooled heat transfer fluid (helium) travels through the magnetic material when heat rejection is required; otherwise the helium stagnates within its pores (pseudo-adiabatic process). Flow of the heat transfer fluid substitutes for the function of a traditional heat switch, creating, essentially, a forced-convection type heat switch. The magnetic bed assembly is periodically magnetized and demagnetized at the center of the conduction-cooled HTS magnet which can stably generate both strong and alternating magnetic field from UT to 3.0 T (0-130 A) with an average ramp rate of 0.24 T s(-1). The cooling capacities of the ADR system at 20K which is the normal boiling point (NBP) of hydrogen, are 11.1 J cycle(-1), 6.3 J cycle(-1) and 1.9J cycle(-1) when the temperature spans are 1 K, 2 K and 3K, respectively. We describe the detailed construction of the ADR system and discuss the test results with the operational parameters (the entrained helium pressure, the mass flow rate of helium and the operating temperature span) in the 20 K region. (C) 2015 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available