4.5 Article

Multimodal Loading Environment Predicts Bioresorbable Vascular Scaffolds' Durability

Journal

ANNALS OF BIOMEDICAL ENGINEERING
Volume 49, Issue 5, Pages 1298-1307

Publisher

SPRINGER
DOI: 10.1007/s10439-020-02673-z

Keywords

Coronary stents; scaffolds; Polylactic acid; Polymer mechanics; Finite element; Animal study; Scaffold fracture; Patient-specific; Design optimization

Funding

  1. Boston Scientific Corporation (Marlborough, MA)
  2. National Institutes of Health [R01 49039]
  3. Fondazione Fratelli Agostino and Enrico Rocca through a Progetto Rocca'' doctoral fellowship
  4. European Project INSILC

Ask authors/readers for more resources

Research has shown that scaffold behavior in the mechanical environment of vessels is affected by multiple loading environments, requiring consideration of different loading modes during benchtop tests to accurately predict locations of structural failures. Ignoring multiple loading environments can lead to undetected design defects, calling for a redefining of consensus evaluation strategies for scaffold performance.
Bioresorbable vascular scaffolds were considered the fourth generation of endovascular implants deemed to revolutionize cardiovascular interventions. Yet, unexpected high risk of scaffold thrombosis and post-procedural myocardial infractions quenched the early enthusiasm and highlighted the gap between benchtop predictions and clinical observations. To better understand scaffold behavior in the mechanical environment of vessels, animal, and benchtop tests with multimodal loading environment were conducted using industrial standard scaffolds. Finite element analysis was also performed to study the relationship among structural failure, scaffold design, and load types. We identified that applying the combination of bending, axial compression, and torsion better reflects incidence observed in-vivo, far more than tranditional single mode loads. Predication of fracture locations is also more accurate when at least bending and axial compression are applied during benchtop tests (>60% fractures at connected peak). These structural failures may be initiated by implantation-induced microstructural damages and worsened by cyclic loads from the beating heart. Ignoring the multi-modal loading environment in benchtop fatigue tests and computational platforms can lead to undetected potential design defects, calling for redefining consensus evaluation strategies for scaffold performance. With the robust evaluation strategy presented herein, which exploits the results of in-vivo, in-vitro and in-silico investigations, we may be able to compare alternative designs of prototypes at the early stages of device development and optimize the performance of endovascular implants according to patients-specific vessel dynamics and lesion configurations in the future.