4.5 Article

Live feedback and 3D photoacoustic remote sensing

Journal

QUANTITATIVE IMAGING IN MEDICINE AND SURGERY
Volume 11, Issue 3, Pages 1033-1045

Publisher

AME PUBL CO
DOI: 10.21037/qims-20-758

Keywords

Photoacoustic (PA); remote; sensing; microscopy; live-feedback; 3D imaging

Funding

  1. Natural Sciences and Engineering Research Council of Canada
  2. Canada Foundation for Innovation
  3. Mitacs Accelerate
  4. University of Waterloo Startup funds
  5. Centre for Bioengineering and Biotechnology, illumiSonics Inc
  6. New frontiers in research fund

Ask authors/readers for more resources

This study introduces a method with low computational overhead for image rendering, resulting in a live display capable of real-time frame rates. 3D imaging with a non-contact label-free reflection-mode technique based on PARS is demonstrated, showing high resolution and sensitivity.
Background: As photoacoustic (PA) techniques progress towards clinical adoption, providing a high-speed live feedback becomes a high priority. To keep up with the instantaneous optical feedback of conventional light microscopes, PA imaging would need to provide a high-resolution video-rate live feed to the user. However, conventional PA microscopy typically trades resolution, sensitivity and imaging speed when optically scanning due to the difficult opto-acoustic confocal geometry. Here, we employ photoacoustic remote sensing (PARS), an all-optical technique that relies on optical confocal geometry, to provide a high resolution live display in a reflection-mode PA architecture. Methods: Employing a conventional x-y galvanometer scanner and a 600 KHz pulse repetition rate laser we implement a system capable of acquiring 2.5 frames per second in 2D. To complement this fast scanning optical system, we implement a computationally inexpensive image reconstruction method that is able to render the frames with minimal overhead, providing a live display. Results: Employing the proposed method, we demonstrate a live feedback with frame rates as high as 2.5 Hz in 2D and also report the first results of 3D imaging with a non-contact label-free reflection-mode technique. The method is validated with phantom studies and in-vivo imaging. Employing a repetition rate of 600 KHz, a live feed of carbon fibers is realized with a C-scan rate of 2.5 Hz. The imaging resolution was measured to be 1.2 mu m, the highest reported for a real-time reflection-mode architecture. The mean and peak SNR were measured to be 44 and 62 dB respectively in-vivo. 3D visualizations of carbon fiber phantoms and mouse ear microvasculature structure are also demonstrated. Conclusions: In summary, we present a method that has a small computational overhead for image rendering, resulting in a live display capable of real-time frame rates. We also report the first 3D imaging with a non-contact label-free reflection-mode PA technique. The all-optical confocal geometry required by PARS is significantly easier to implement and maintain than the opto-acoustic geometry of conventional PA microscopy techniques. This results in a system capable of high resolution and sensitivity, imaging at realtime rates. The authors believe this work represents a vital step towards a clinical high-resolution reflection mode video-rate PA imaging system.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available