Drastic improvement in detection limits in energy dispersive X-ray fluorescence geometry utilizing micro-focused bremsstrahlung excitation in thin-film sample specimen†

Journal

JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY
Volume 36, Issue 4, Pages 803-812

Publisher

ROYAL SOC CHEMISTRY
DOI: 10.1039/d0ja00499e

Keywords

-

Funding

  1. Radiochemistry and Isotope Group

Ask authors/readers for more resources

An improvement in the detection limit was achieved using a lab-based micro-X-ray fluorescence spectrometer, with a simple and straightforward methodology that does not require complicated alignment procedures. This method can be used for the analysis of ultra-trace elemental concentrations in water samples.
An excellent improvement in the detection limit is achieved using a lab-based micro-X-ray fluorescence (micro-XRF) spectrometer equipped with a low-power X-ray tube that utilizes the entire bremsstrahlung spectrum emitted from the tube, for excitation. The beam was further passed through polycapillary optics in order to focus it over a spot of 35 mu m x 50 mu m. The minimum detection limit (MDL) achieved using the present methodology is down to 0.4-4 ng mL(-1) for elements ranging from medium to high Z. For some elements, the as-obtained MDL is almost 6-60 times lower than that obtained using the lab-based total reflection X-ray fluorescence (TXRF) spectrometer using the same excitation source. This is the lowest detection limit achieved to date using lab-based XRF instrument in energy dispersive X-ray fluorescence (EDXRF) geometry to the best of our knowledge. Further, the instrumentation is very simple, straightforward and does not involve any complicated alignment procedure as in the TXRF geometry. The developed methodology requires deposition and drying of only 5 mu L of the liquid sample specimen on a thin transparent scotch tape to form a thin film sample specimen and it can be directly used for measurements. Using this methodology, we could determine trace elemental concentration in water samples at an ultra-trace level (few ng mL(-1)) without any complicated pre-concentration or alignment procedure. As the developed methodology is very simple and less time-consuming, it is comparable with the TXRF technique for the routine analysis of different water samples with elements present at ultra-trace levels.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available