4.6 Article

Cadmium sulfide quantum dots anchored on reduced graphene oxide for the electrochemical detection of metronidazole

Journal

NEW JOURNAL OF CHEMISTRY
Volume 45, Issue 6, Pages 3022-3033

Publisher

ROYAL SOC CHEMISTRY
DOI: 10.1039/d0nj05501h

Keywords

-

Funding

  1. Ministry of Science and Technology, Taiwan [MOST 107-2113-M-027-005-MY3]

Ask authors/readers for more resources

In this study, CdS QDs were successfully synthesized and anchored on rGO nanosheets via a simple sonication method to enhance their electron charge transfer properties. The composite was characterized using various analytical techniques and showed a well-dispersed morphology. With the synergistic effect between rGO and CdS QDs, the composite exhibited superior electrochemical response for the detection of MTZ, with wide linear range and low detection limit. Additionally, the proposed electrode demonstrated satisfactory recovery results in milk samples.
In this research, the metal-organic-based synthesis of cadmium sulfide quantum dots (CdS QDs) was performed. The CdS QDs were anchored on reduced graphene oxide (rGO) nanosheets using a simple sonication technique; this can enhance the electron charge transfer properties of the CdS QDs. The successful formation of the CdS QDs@rGO composite was revealed using various analytical techniques, such as X-ray diffractometry (XRD), Fourier-transform infrared spectroscopy (FT-IR), Raman spectroscopy, transmission electron microscopy (TEM), and X-ray photoelectron spectroscopy (XPS). Optical and morphological analysis revealed that the composite took the form of a well-dispersed suspension. The as-prepared composite was fabricated on a glassy carbon electrode (GCE) for the electrochemical detection of metronidazole (MTZ). Owing to the synergistic effect between rGO and CdS QDs, a superior electrochemical response was obtained using cyclic voltammetry analysis. Quantitative analysis using the differential pulse voltammetry (DPV) technique revealed a wide linear MTZ concentration range from 0.1 to 203.1 mu M with a low-level detection limit of 0.053 mu M. Furthermore, the practical applicability of the proposed electrode was assessed in milk samples with satisfactory recovery results.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available