4.6 Article

Ultrasensitive simultaneous detection of ascorbic acid, dopamine, uric acid and acetaminophen on a graphitized porous carbon-modified electrode

Journal

NEW JOURNAL OF CHEMISTRY
Volume 45, Issue 4, Pages 1863-1875

Publisher

ROYAL SOC CHEMISTRY
DOI: 10.1039/d0nj04806b

Keywords

-

Funding

  1. RGNF (Rajiv Gandhi National Fellowship) from University Grants Commission, New Delhi [F-17.1/2016-17/RGNF-2015-17-SC-TAM-21830]
  2. UGC, New Delhi

Ask authors/readers for more resources

The development of active and defective sites in mesoporous carbon materials is crucial for high-performance sensors. NHCS-1000, with improved surface area, porosity, and N-doping, showed enhanced electrocatalytic activity and was successfully utilized for the simultaneous detection of multiple analytes.
The development of active and defective sites containing mesoporous carbon material is highly crucial for high-performance sensors. In this work, N-doped hollow carbon sphere (NHCS) materials with high surface area and large volume of graphitic and pyridinic N were obtained by variation of the carbonization temperature between 700-1000 degrees C. Here, dopamine hydrochloride and tetraethyl orthosilicate (TEOS) were used as C, N and silica precursors, with both involved in silica-poly (dopamine) (PDA) sphere formation followed by silica etching to NHCS. Among NHCS materials, NHCS-1000 exhibited an improved surface area, porosity, layer thickness, defective sites and graphitic along with pyridinic sites. An NHCS-modified glassy carbon electrode (NHCS/GCE) was fabricated and successfully used for the simultaneous sensing of ascorbic acid (AA), uric acid (UA), dopamine (DA) and acetaminophen (AC). All NHCS materials exhibited electrocatalytic activity towards the oxidation of these four biologically important analytes. Compared with other carbon materials, NHCS-1000 showed a higher electrocatalytic activity. Hence, the NHCS-1000-modified electrode was used for the further electrochemical sensing of multiple analytes. The limit of detection (LOD) values were 0.135, 0.012, 0.131 and 0.095 mu M, respectively, for AA, UA, DA and AC. From the calibration plot, the calculated sensitivity values were: 0.029 mA cm(-2) mM(-1) for AA, 0.73 mA cm(-2) mM(-1) for DA, (0.53; 0.069 mA cm(-2) mM(-1)) for UA, and (0.53; 0.765 mA cm(-2) mM(-1)) for AC. The linear ranges of AA, DA, UA and AC were 0.01-7.0 mM, 0.001-1.5 mM, (0.005-1.0; 2.0-6.0 mM), and (0.05-1.0; 2.0-6.0 mM), respectively. The NHCS-1000-modified electrode showed good selectivity and linear range. The proposed NHCS-1000/GCE was effectively used for the detection of multiple analytes in the real samples of urine, serum, ascorbic acid and commercially available tablets.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available