This study evaluated the clinical value of intraoperative nerve monitoring in thyroidectomies by comparing procedure times for surgeries performed with and without IONM. The results showed that IONM reduced the time needed for recurrent laryngeal nerve identification, providing reassurance to surgeons and not significantly impacting setup and total operative times.
Objective To evaluate the clinical value of intraoperative nerve monitoring (IONM) by comparing the procedure times for thyroidectomies performed with and without IONM. Methods A prospective, randomized, controlled study was conducted on 32 patients (representing 41 nerves at risk) undergoing thyroidectomies carried out by two experienced head and neck surgeons (CC & WP). Sixteen thyroidectomies were performed without IONM (the non-IONM group), while 16 thyroidectomies were performed with IONM (the IONM group). The measured datapoints were setup time, time to visual identification of the recurrent laryngeal nerve (RLN), time to confirm the RLN electrophysiologically, dissection time, and total operative time. Results With both surgeons, the IONM group had shorter visual times to RLN identification than the non-IONM group (CC: 3.7 minutes vs 5.3 minutes; WP: 3.4 minutes vs 9.7 minutes). Additionally, the electrophysiological identification time for the IONM group was shorter than the visual identification time for the non-IONM group. The setup times, dissection times, and total operative times of the 2 groups did not significantly differ (P > .05). No RLN injuries were observed. Conclusions IONM reduces the time needed for RLN identification in thyroidectomies. Functional RLN confirmation can reassure surgeons of the operative results. Moreover, use of IONM does not significantly impact setup and total operative times. Level of evidence 2.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available