4.6 Article

Carbon nitride quantum dots tethered on CNTs for the electrochemical detection of dopamine and uric acid†

Journal

NEW JOURNAL OF CHEMISTRY
Volume 45, Issue 14, Pages 6263-6272

Publisher

ROYAL SOC CHEMISTRY
DOI: 10.1039/d1nj00555c

Keywords

-

Funding

  1. Department of Science and Technology (DST), Government of India
  2. Kerala State Council for Science, Environment, and Technology (KSCSTE), Kerala, India
  3. University Grants Commission

Ask authors/readers for more resources

A nanocomposite material of CNQDs/f-CNT with high electro-catalytic activity for selective and sensitive detection of DA and UA has been successfully prepared. This material was applied for the detection of DA and UA in human serum, achieving a satisfactory recovery rate with less than 4% error in experiments.
The precise measurement of dopamine (DA) level is of great concern, since its abnormal levels produce several physiological and pathological effects. The detection of a trace amount of DA in the presence of uric acid (UA) and ascorbic acid (AA) still remains a challenge. A zero dimensional-one dimensional (0D-1D) architecture is prepared from carbon nitride quantum dots (CNQDs) and functionalized multiwalled carbon nanotubes (f-CNT). A f-CNT network with anchored CNQDs is synthesized for the first time through a hydrothermal treatment of an aqueous solution containing -COOH functionalized CNTs and -COOH and -SO3H functionalized carbon nitride nanosheets (CNNSs). The high electro-catalytic activity of CNQDs/f-CNT has been utilized for the selective and sensitive electrochemical detection of DA and UA. The CNQDs/f-CNT nanocomposite was used as a modifier for the glassy carbon electrode (GCE), and produces sharp distinguishable anodic peaks for DA, UA, and AA in its ternary mixture. Differential pulse voltammetry (DPV) was performed for the selective and simultaneous detection of DA and UA in the presence of 1 mM AA. The amperometric technique was also used for the detection of DA (linear range: 1 nM -350 mu M, LOD: 19 nM) and UA (linear range: 1-260 mu M, LOD: 0.173 mu M). This nanocomposite was employed for the detection of DA and UA by spiking various concentrations of analytes in human blood serum and obtained recovery within 4% error.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available