4.6 Article

Ultrasensitive detection of cyclin D1 by a self-enhanced ECL immunosensor based on Bi2S3 quantum dots

Journal

ANALYST
Volume 146, Issue 6, Pages 2057-2064

Publisher

ROYAL SOC CHEMISTRY
DOI: 10.1039/d0an02296a

Keywords

-

Funding

  1. Jiangsu Key Laboratory of Biofunctional Materials, Projects of Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, National and Local Joint Engineering Research Center of Biomedical Functional Materials

Ask authors/readers for more resources

The study successfully synthesized Bi2S3 QDs with excellent performance using the biomineralization method, and investigated their ECL characteristics and mechanisms for the first time. By using an ECL immunosensor for CCND1 detection, a wide detection range and extremely low detection limit were demonstrated.
Bismuth sulfide quantum dots (Bi2S3 QDs), which have excellent optical and thermoelectric properties, represent a green and non-toxic semiconductor material that has been widely used in catalysis and photoelectric conversion devices. At present, research on this material has gradually expanded into the biological field. Herein, the biomineralization method mediated by bovine serum albumin (BSA) was utilized to synthesize Bi2S3 QDs with monodispersity, excellent colloidal stability, and good biocompatibility. This is the first study on the electrochemiluminescence (ECL) characteristics of Bi2S3 QDs and related ECL mechanisms in detail. In addition, on the basis of Bi2S3 QDs, an ECL immunosensor was used for the ultrasensitive measurement of cyclin D1 (CCND1). The composite material, namely Au@Cu-Bi2S3 QDs was used as a high-sensitivity ECL probe, in which AuNPs were connected with Bi2S3 QDs through a copper(ii) ion bridge. PDA-AgNPs made of dopamine (DA) and silver nanoparticles (AgNPs) were utilized as a carrier for fixing the primary antibody (Ab(1)), ultimately presenting a relatively wide detection range of 10 fg mL(-1)-1 mu g mL(-1). Moreover, quite a low detection limit (6.34 fg mL(-1)) was also obtained for an assay of CCND1. Results indicated that the immunosensor can provide a potential platform with fine stability and creditable reproducibility for clinical diagnosis.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available