4.7 Article

Increased Symmetry of Lower-Limb Amputees Walking With Concurrent Bilateral Vibrotactile Feedback

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TNSRE.2020.3034521

Keywords

Legged locomotion; Haptic interfaces; Training; Vibrations; Foot; Sensor phenomena and characterization; Gait symmetry; haptic interfaces; lower-limb amputation; sensory aids

Funding

  1. European Commission through the CYBERnetic LowEr-Limb CoGnitive Ortho-prosthesiS (CYBERLEGs) Plus Plus Project within the H2020 Framework [731931]
  2. European Commission through the CYBERnetic LowEr-Limb CoGnitive Ortho-prosthesiS (CYBERLEGs) Plus Plus Project within H2020-ICT-25-2016-2017

Ask authors/readers for more resources

Augmented sensory feedback in rehabilitation programs can effectively improve temporal gait symmetry in lower-limb amputees, leading to better overall gait quality. Using a wearable device delivering vibrations synchronized to gait events during ground-level training showed promising short-term results.
Gait asymmetry in lower-limb amputees can lead to several secondary conditions that can decrease general health and quality of life. Including augmented sensory feedback in rehabilitation programs can effectively mitigate spatiotemporal gait irregularities. Such benefits can be obtained with non-invasive haptic systems representing an advantageous choice for usability in overground training and every-day life. In this study, we tested a wearable tactile feedback device delivering short-lasting (100ms) vibrations around the waist syncronized to gait events, to improve the temporal gait symmetry of lower-limb amputees. Three above-knee amputees participated in the study. The device provided bilateral stimulations during a training program that involved ground-level gait training. After three training sessions, participants showed higher temporal symmetry when walking with the haptic feedback in comparison to their natural walking (resulting symmetry index increases of +2.8% for Subject IDA, +12.7% for Subject IDB and +2.9% for Subject IDC). One subject retained improved symmetry (Subject IDB,+14.9%) even when walking without the device. Gait analyses revealed that higher temporal symmetry may lead to concurrent compensation strategies in the trunk and pelvis. Overall, the results of this pilot study confirm the potential utility of sensory feedback devices to positively influence gait parameters when used in supervised settings. Future studies shall clarify more precisely the training modalities and the targets of rehabilitation programs with such devices.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available