4.6 Article

Modeling and Optimal Tuning of Hybrid ESS Supporting Fast Active Power Regulation of Fully Decoupled Wind Power Generators

Journal

IEEE ACCESS
Volume 9, Issue -, Pages 46409-46421

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/ACCESS.2021.3066134

Keywords

Power system stability; Frequency control; Batteries; Generators; Frequency synchronization; Frequency measurement; Optimization; Fast active power-frequency response; ultracapacitor model; hybrid energy storage system; fully decoupled wind power generator; mean-variance mapping optimization

Ask authors/readers for more resources

This paper investigates the improvement of frequency response of fully decoupled wind power generators by introducing ultracapacitors and hybrid energy storage systems in real-time simulations, and discusses the trade-off between frequency performance and cost through optimization. The results show that fast UC power injection enhances the frequency response speed, with virtual synchronous power providing faster frequency support compared to other control strategies.
The frequency stability of the power system is challenged by the high penetration of power electronic interfaced renewable energy sources (RES). This paper investigates the improvements of the frequency response of fully decoupled wind power generators (FDWG) by proposing a novel generic model implementation of ultracapacitors (UC) within a hybrid scheme in real-time simulations of wind power plants. UCs are selected as ideal power sources in fast active power-frequency control due to their high power density and fast-reacting speed. Batteries and UCs combined hybrid energy storage systems (HESS) are formed to complement their characteristics. Droop-based and frequency derivative-based control and virtual synchronous power (VSP) are the selected control strategies to support power system frequency stability. The best trade-off between frequency performance and HESS cost is found by solving a proposed optimization problem formulation. The proposed optimization problem is used to define the HESS size and the controller parameters. The optimization results show how the fast active power-frequency response is enhanced by the fast UC power injection. It also shown that VSP leads to faster frequency support than the droop-based control and the frequency derivative control.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available