4.6 Review

Rapid developments in lateral flow immunoassay for nucleic acid detection

Journal

ANALYST
Volume 146, Issue 5, Pages 1514-1528

Publisher

ROYAL SOC CHEMISTRY
DOI: 10.1039/d0an02150d

Keywords

-

Funding

  1. National Key Research and Development Program of China [2017FYA0205303, 2017FYA0205301]
  2. National Natural Science Foundation of China [82020108017]
  3. Shanghai Science and Technology Fund [15DZ225200]
  4. Medical Engineering Cross Project of SJTU [ZH2018QNA03, YG2019QNB09]

Ask authors/readers for more resources

This review discusses two main research directions of lateral flow nucleic acid tests, one involving the incorporation of isothermal amplification methods for increased sensitivity, and the other focusing on the development of novel labeling materials for improved quantifiability. Future research will focus on integrating the entire testing process into microfluidic systems and combining with molecular diagnostic tools to facilitate rapid and accurate testing.
Recently, lateral flow assay (LFA) for nucleic acid detection has drawn increasing attention in the point-of-care testing fields. Due to its rapidity, easy implementation, and low equipment requirement, it is well suited for use in rapid diagnosis, food authentication, and environmental monitoring under source-limited conditions. This review will discuss two main research directions of lateral flow nucleic acid tests. The first one is the incorporation of isothermal amplification methods with LFA, which ensures an ultra-high testing sensitivity under non-laboratory conditions. The two most commonly used methodologies will be discussed, namely Loop-mediated Isothermal Amplification (LAMP) and Recombinase Polymerase Amplification (RPA), and some novel methods with special properties will also be introduced. The second research direction is the development of novel labeling materials. It endeavors to increase the sensitivity and quantifiability of LFA testing, where signals can be read and analyzed by portable devices. These methods are compared in terms of limits of detection, detection times, and quantifiabilities. It is anticipated that future research on lateral flow nucleic acid tests will focus on the integration of the whole testing process into a microfluidic system and the combination with molecular diagnostic tools such as clustered regularly interspaced short palindromic repeats to facilitate a rapid and accurate test.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available