4.6 Article

Highly selective simultaneous determination of Cu(ii), Co(ii), Ni(ii), Hg(ii), and Mn(ii) in water samples using microfluidic paper-based analytical devices

Journal

ANALYST
Volume 146, Issue 7, Pages 2229-2239

Publisher

ROYAL SOC CHEMISTRY
DOI: 10.1039/d0an02200d

Keywords

-

Funding

  1. Development and Promotion of Science and Technology Talents Project (Royal Government of Thailand scholarship) under Henry Group (Colorado State University, United States)
  2. Environmental Analysis Research Unit (Chulalongkorn University, Thailand)
  3. National Institutes of Health [R43 ES031906-01]

Ask authors/readers for more resources

A new paper-based analytical device design was fabricated using a wax printing method for simultaneous determination of Cu(ii), Co(ii), Ni(ii), Hg(ii), and Mn(ii). By incorporating two pretreatment zones, masking agents were able to remove interfering ions effectively, resulting in low detectable concentrations and linear ranges for the heavy metal ions.
A new paper-based analytical device design was fabricated by a wax printing method for simultaneous determination of Cu(ii), Co(ii), Ni(ii), Hg(ii), and Mn(ii). Colorimetry was used to quantify these heavy metal ions using bathocuproine (Bc), dimethylglyoxime (DMG), dithizone (DTZ), and 4-(2-pyridylazo) resorcinol (PAR) as complexing agents. The affinity of complexing agents to heavy metal ions is dependent on the formation constant (K-f). To enhance the selectivity for heavy metal ion determination, the new device was designed with two pretreatment zones, where masking agents remove the interfering ions. It was found that two pretreatment zones worked better than a single pretreatment zone at removing interferences. The reaction time, sample and complexing agent volumes, and complexing agent concentrations were optimized. The analytical results were achieved with the lowest detectable concentrations of 0.32, 0.59, 5.87, 0.20, and 0.11 mg L-1 for Cu(ii), Co(ii), Ni(ii), Hg(ii), and Mn(ii), respectively. The linear ranges were found to be 0.32-63.55 mg L-1 (Cu(ii)), 0.59-4.71 mg L-1 (Co(ii)), 5.87-352.16 mg L-1 (Ni(ii)), 0.20-12.04 mg L-1 (Hg(ii)), and 0.11-0.55 mg L-1 (Mn(ii)). The lowest detectable concentration and linearity for the five metal ions allow the application of this device for the determination of heavy metal ions in various water samples. The sensor showed high selectivity and efficiency for simultaneous determination of Cu(ii), Co(ii), Ni(ii), Hg(ii), and Mn(ii) in drinking, tap, and pond water samples on a single device and detection with the naked eye. The results illustrated that the proposed sensor showed good accuracy and precision agreement with the standard ICP-OES method.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available