4.6 Article

An Anti-migration Self-expandable and Removable Metal Stent for Crohn's Disease Strictures: A Nationwide Study From GETAID and SFED

Journal

JOURNAL OF CROHNS & COLITIS
Volume 15, Issue 4, Pages 521-528

Publisher

OXFORD UNIV PRESS
DOI: 10.1093/ecco-jcc/jjaa208

Keywords

Crohn's disease; stent; anti-migration; digestive obstruction

Funding

  1. Association Francois Aupetit [AFA]
  2. Life Partner Europe

Ask authors/readers for more resources

The study showed that the anti-migration stent is safe and effective in about half of Crohn's disease patients, with a relatively high success rate in the long term follow-up. Surgical intervention or balloon dilation may be necessary for some patients, but the overall success rate is still considerable.
Background and Aims: In Crohn's disease, strictures are frequent and may require surgical resection or endoscopic balloon dilation. An anti-migration, removable and shaped self-expandable metal stent is available. We evaluated its effectiveness and safety in a real-life setting. Methods: All centres were asked to collect retrospectively or prospectively all data on patients who had a stent for a stricture. The anti-migration stent [Hanarostent HRC-20-080-230-MITech, Seoul, South Korea] was maintained 7 days before its extraction during a second colonoscopy. Short- and long-term efficacy and safety outcomes were evaluated. Results: A total of 46 patients were enrolled. Strictures were anastomotic in 73.9% of cases. The median length of the stricture evaluated by cross-sectional imaging and during colonoscopy was 3.1 1.7 and 2.7 +/- 1.4 cm, respectively. Immediate success [no obstructive symptom at Day 30] was reported in 93.5% of cases (95% confidence interval [CI] = [86.3; 99.9]). Sixteen patients needed a new balloon dilation [n = 8] or surgery [n = 8]. The overall success rate [obstruction-free without any intervention] was 58.7% [n = 27] after a median follow-up of 26 months [8-41 months]. No perforation occurred and three migrations were observed [6.5%]. Perianal disease (hazard ratio [HR] = 0.1 [0.02; 0.58]) and discontinuation of an immunosuppressant (0.12 [0.02; 0.86]), were associated with a lower probability of success, whereas performing imaging (HR = 5.3 [1.2; 23.5]) before stent placement was associated with success. Conclusions: The anti-migration stent is safe and effective in about half of patients, with no perforation reported in this study, and has an extremely low migration rate.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available