4.6 Article

Glucose oxidase decorated fluorescent metal-organic frameworks as biomimetic cascade nanozymes for glucose detection through the inner filter effect

Journal

ANALYST
Volume 146, Issue 13, Pages 4188-4194

Publisher

ROYAL SOC CHEMISTRY
DOI: 10.1039/d1an00847a

Keywords

-

Funding

  1. National Natural Science Foundation of China [21673022]
  2. Fundamental Research Funds for the Central Universities

Ask authors/readers for more resources

The integration of NH2-MIL-101 with GOx achieved efficient biomimetic cascade catalysis for one-step glucose detection. The method was successfully applied in human serum and saliva, showing potential applications in diverse biological samples and even medical diagnosis.
Metal-organic frameworks (MOFs) as a peroxidase mimic have been integrated with glucose oxidase (GOx) to achieve one-step glucose detection. However, limited by the loading amount of GOx, the performances of the developed glucose sensing assays still remain to be further improved to meet sensing requirements in diverse biological samples. Herein, with Fe3+ as the metal ion and 2-amino-benzenedicarboxylic acid as a ligand, a fluorescent Fe-based organic framework (NH2-MIL-101) with peroxidase-like activity was synthesized. Due to the large specific surface area (791.75 m(2) g(-1)), 68 mu g mg(-1) GOx could be immobilized through the amidation coupling reaction, and the product was designated GOx@NH2-MIL-101. With OPD as the substrate, Gox@NH2-MIL-101 achieved highly efficient biomimetic cascade catalysis for one-step glucose detection through an inner filter effect: upon reacting with glucose, GOx@NH2-MIL-101 catalytically oxidized glucose using dissolved O-2, and the produced H2O2 concurrently oxidized o-phenylenediamine (OPD) to oxidized OPD (oxOPD), accompanied by the fluorescence of GOx@NH2-MIL-101 at 456 nm being quenched and that of oxOPD at 565 nm being enhanced. With the fluorescent ratio F-565/F-456 used as a readout signal, a wide linear range of 0.1-600 mu M was obtained, and the detection limit was 0.0428 mu M. Based on the excellent selectivity and high stability of GOx@NH2-MIL-101, the developed assay was successfully applied to glucose detection in human serum and saliva, presenting potential applications in diverse biological samples and even medical diagnosis.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available