Journal
EXPERIMENTAL THERMAL AND FLUID SCIENCE
Volume 82, Issue -, Pages 482-492Publisher
ELSEVIER SCIENCE INC
DOI: 10.1016/j.expthermflusci.2016.12.006
Keywords
Flat heat pipe; Copper foam; Wick columns (WC); Evaporator; Condenser
Ask authors/readers for more resources
Experimental investigations of thermal performance of a flat heat pipe (FHP) with and without wick columns were investigated. Copper metal foam fabricated by lost carbonate sintering process and characterized by Scanning Electron Microscope (SEM) was used as wick structure. The effect of heat input, cooling water flow rate, cooling water temperature and fill ratio on the thermal response of the FHP is presented. Results showed that the heat transfer coefficient increases with increased Reynolds number and cooling water temperature but decreases with increased heat input and amount of fill ratio. It was found that increasing the wick volume by inserting additional wick columns improves the FHP performance, due to the decreased thermal resistance with increased fluid movement in these additional wick columns. The experimental results were compared with that of analytical calculations at steady state and a good agreement was observed between them. (C) 2016 Elsevier Inc. All rights reserved.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended
No Data Available