4.4 Article

Numerical investigation on low-frequency noise damping performances of Helmholtz resonators with an extended neck in presence of a grazing flow

Journal

Publisher

SAGE PUBLICATIONS LTD
DOI: 10.1177/14613484211020584

Keywords

Helmholtz resonator; transmission loss; noise damping; extended neck; grazing flow; aeroacoustics

Categories

Funding

  1. Jiangsu University of Science and Technology

Ask authors/readers for more resources

This study focuses on maximizing the noise damping performance of resonators by optimizing and applying extended neck designs, showing that extended neck designs can achieve higher transmission loss performance over a broader frequency range.
In this work, modified designs of Helmholtz resonators with extended deflected neck are proposed, numerically evaluated and optimized aiming to achieve a better transmission loss performance over a broader frequency range. For this, 10 Helmholtz resonators with different extended neck configurations (e.g. the angle between extended neck and the y-axis) in the presence of a grazing flow are assessed. Comparison is then made between the proposed resonators and the conventional one, i.e. in the absence of an extended neck (i.e. Design A). For this, a two-dimensional linearized Navier Stokes equations-based model of a duct with the modified Helmholtz resonator implemented was developed in frequency domain. The model was first validated by comparing its numerical predictions with the experimental results available in the literature and the theoretical results. The model was then applied to evaluate the noise damping performance of the Helmholtz resonator with (1) an extended neck on the upstream side (Design B); (2) on the downstream side (Design C), (3) both upstream and downstream sides (Design D), (4) the angle between the extended neck and the y-axis, i.e. (a) 0 degrees, (b) 30 degrees, and (c) 45 degrees, (d) 48.321 degrees. In addition, the effects of the grazing flow Mach number (Ma) were evaluated. It was found that the transmission loss peaks of the Helmholtz resonator with the extended neck was maximized at Ma = 0.03 than at the other Mach numbers. Conventional resonator, i.e. Design A was observed to be associated with a lower transmission loss performance at a lower resonant frequency than those as observed on Designs B-D. Moreover, the optimum design of the proposed resonators with the extended neck is shown to be able to shift the resonant frequency by approximately 90 Hz, and maximum transmission loss could be increased by 28-30 dB. In addition, the resonators with extended necks are found to be associated with two or three transmission loss peaks, indicating that these designs have a broader effective frequency range. Finally, the neck deflection angles of 30 degrees and 45 degrees are shown to be involved with better transmission loss peaks than that with a deflection angle of 0 degrees. In summary, the present study sheds light on maximizing the resonator's noise damping performances by applying and optimizing an extended neck.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available