4.6 Article

Gold nanorod self-assembly on a quartz crystal microbalance: an enhanced mercury vapor sensor

Journal

ENVIRONMENTAL SCIENCE-NANO
Volume 8, Issue 11, Pages 3273-3281

Publisher

ROYAL SOC CHEMISTRY
DOI: 10.1039/d1en00677k

Keywords

-

Funding

  1. Australian Research Council (ARC) through the Industrial Transformation Research Hubs (ITRP) [1H200100010]
  2. Cooperative Research Centres Projects (CRC-P) [CRCPIX000240]
  3. ARC [DP150101939]
  4. Department of Education and Training, Government of Australia
  5. ARC through the Discovery Early Career Researcher Award (DECRA) [DE190100986]
  6. Australian Research Council [DE190100986] Funding Source: Australian Research Council

Ask authors/readers for more resources

The study revealed that gold nanorods show higher response magnitude and repeatability in detecting elemental mercury vapor, with good detection performance at low concentrations, but decreased selectivity in the presence of ammonia and water vapor.
It is now well documented that mercury is extremely toxic to both humans and the environment. A close-packed gold nanorod (Au-NR) monolayer was deposited on a titanium-based quartz crystal microbalance (QCM) and its performance for elemental mercury (Hg-0) vapor sorption and detection was compared with that of a typical gold thin film (Au CTRL) based QCM device. The developed Au-NR based Hg-0 sensor showed an up to similar to 1.7 times higher response magnitude than its Au CTRL counterpart when exposed to Hg-0 vapor concentrations of 0.21 to 3.26 mg m(-3) at two different operating temperatures of 30 and 75 degrees C. The repeatability of the Au-NR sensor was calculated to be >90% when exposed to a series of sorption/desorption events with a Hg-0 vapor concentration of 3.26 mg m(-3). The calibration curves (i.e. response magnitudes vs. Hg-0 concentrations) of the Au-NR sensor were found to follow the Langmuir extension isotherm, indicating the sensor's suitability to detect relatively low concentrations (ppb levels) of Hg-0 vapor. Furthermore, the newly developed Au-NR sensor showed good selectivity (similar to 97%) toward Hg-0 vapor when acetaldehyde co-existed in the gas mix. However, the selectivity of the sensor decreased to 66% and 67% when Hg-0 vapor was detected in the presence of ammonia and water vapor, respectively. The selectivity data from the tested sensors were analysed to understand the selectivity performance of Au NRs toward Hg-0 vapor in the presence of different gas species in order to implement improvements in developing the sensor for real world applications.