4.6 Article

Application and comparison of the FADES, MADIT, and SHFM-D risk models for risk stratification of prophylactic implantable cardioverter-defibrillator treatment

Journal

EUROPACE
Volume 19, Issue 1, Pages 72-80

Publisher

OXFORD UNIV PRESS
DOI: 10.1093/europace/euw005

Keywords

Implantable cardioverter-defibrillator; Risk stratification; Primary prevention

Funding

  1. Department of Cardiology, Leiden University Medical Center, The Netherlands

Ask authors/readers for more resources

Aims Implantable cardioverter-defibrillator (ICD) treatment is beneficial in selected patients. However, it remains difficult to accurately predict which patients benefit most from ICD implantation. For this purpose, different risk models have been developed. The aim was to validate and compare the FADES, MADIT, and SHFM-D models. Methods and results All patients receiving a prophylactic ICD at the Leiden University Medical Center were evaluated. Individual model performance was evaluated by C-statistics. Model performances were compared using net reclassification improvement (NRI) and integrated differentiation improvement (IDI). The primary endpoint was non-benefit of ICD treatment, defined as mortality without prior ventricular arrhythmias requiring ICD intervention. A total of 1969 patients were included (age 63 +/- 11 years; 79% male). During a median follow-up of 4.5 +/- 3.9 years, 318 (16%) patients died without prior ICD intervention. All three risk models were predictive for event-free mortality (all: P < 0.001). The C-statistics were 0.66, 0.69, and 0.75, respectively, for FADES, MADIT, and SHFM-D (all: P, 0.001). Application of the SHFM-D resulted in an improved IDI of 4% and NRI of 26% compared with MADIT; IDI improved 11% with the use of SHFM-D instead of FADES (all: P, 0.001), but NRI remained unchanged (P = 0.71). Patients in the highest-risk category of the MADIT and SHFM-D models had 1.7 times higher risk to experience ICD non-benefit than receive appropriate ICD interventions [MADIT: mean difference (MD) 20% (95% CI: 7-33%), P = 0.001; SHFM-D: MD 16% (95% CI: 5-27%), P = 0.005]. Patients in the highest-risk category of FADES were as likely to experience ICD intervention as ICD non-benefit [MD 3% (95% CI: -8 to 14%), P = 0.60]. Conclusion The predictive and discriminatory value of SHFM-D to predict non-benefit of ICD treatment is superior to FADES and MADIT in patients receiving prophylactic ICD treatment.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available