4.6 Article

Assessment of Timber Roof Structures before and after Earthquakes

Journal

BUILDINGS
Volume 11, Issue 11, Pages -

Publisher

MDPI
DOI: 10.3390/buildings11110528

Keywords

inspection; assessment; timber roof; seismic area; earthquake; case study; Zagreb

Funding

  1. Croatian Science Foundation [UIP-2019-04-3749]

Ask authors/readers for more resources

The importance of assessing and reconstructing existing timber structures, especially for exposed elements like timber roofs, has been highlighted. The study focused on criteria for evaluating load-bearing timber structures in seismic active areas, as well as the feasibility of non-destructive and semi-destructive testing methods through a case study.
The global objective of sustainable development has been greatly directed toward the preservation of existing structures. Therefore, condition assessment and reconstruction of existing timber structures have been gaining importance in recent times. This is particularly evident on timber roofs whose elements are exposed to degradation, either because of rheological effects or due to the direct influence of moisture and biological factors. In case of accidental events, such as an earthquake, the question of the structure's condition is essential for the condition of the entire building. In order to prove the load-bearing capacity and serviceability of existing structures, as well as to check the need for reconstruction, it is necessary to define crucial parameters that are influencing the condition of materials, elements, and systems. Although there are many non destructive testing methods, the frequency and scope of their use, as well as the decision-making approach, have not been defined. In the paper, non-destructive and semi-destructive methods frequently used for timber structures are explained. A systematic review of criteria to be used in the assessment of load-bearing timber structures in a seismic active area was the main objective of this paper as well as the illustration of non-destructive and semi-destructive test methods through a case study involving roof construction of a hundred-year-old building in Zagreb, Croatia. Pre- and post-earthquake inspection was made. The overall condition of the roof structure after two significant earthquakes can be assessed as satisfactory given that the observed system is a large-span and massive roof structure. The presented results and identification of typical damages after the earthquake are presented in order to facilitate policy makers and for the future implementation of development strategies in the renovation of the city.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available