4.0 Article

High-Temperature Ignition of Propane-Oxygen-Argon Mixtures in a Shock Tube at A Pressure of 30 Atm

Journal

RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY B
Volume 15, Issue 5, Pages 827-832

Publisher

MAIK NAUKA/INTERPERIODICA/SPRINGER
DOI: 10.1134/S1990793121050067

Keywords

propane; argon; ignition delay time; shock tube; high pressures

Funding

  1. Russian Foundation for Basic Research [20-51-00003 (Bel_a)]
  2. Ministry of Science and Higher Education of the Russian Federation [AAAA-A19-119012990112-4]

Ask authors/readers for more resources

The ignition delay times of propane in propane-oxygen mixtures diluted with argon are measured behind the front of the reflected shock wave in a shock tube. The results show that the ignition delay time of propane increases with an increase in the excess fuel ratio phi in the studied temperature range. Comparing the obtained data with other measurements reveals that at low temperatures (T <= 1000 K), the dependence of the ignition delay time on phi is opposite.
The ignition delay times are measured in propane-oxygenl mixtures strongly diluted with argon. The experiments are carried out in a shock tube behind the front of the reflected shock wave in the temperature range T = 1250-1770 K at pressure p = 30 atm and the following values of the excess fuel ratios: phi = 0.5, 1.0, and 2.0. It is shown that, in the region of the studied temperatures, the ignition delay time in propane increases with an increase in phi. The obtained data are compared with the results of other measurements, which shows that at low temperatures (T <= 1000 K) the dependence of the ignition delay time on phi has the opposite character.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.0
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available