4.7 Article

Feasibility of Single-Time-Point Dosimetry for Radiopharmaceutical Therapies

Journal

JOURNAL OF NUCLEAR MEDICINE
Volume 62, Issue 7, Pages 1006-1011

Publisher

SOC NUCLEAR MEDICINE INC
DOI: 10.2967/jnumed.120.254656

Keywords

dosimetry; quantitation; radiopharmaceutical therapy; SPECT; single-time-point

Funding

  1. National Institutes of Health/Canadian Institutes of Health Research (CIHR) Quantitative Imaging Network [137993]
  2. German Research Foundation [GRK2274]
  3. Fonds de recherche du Quebec-Sante
  4. CIHR [MOP-142233]

Ask authors/readers for more resources

The study analyzed two STP dosimetry methods and evaluated dose errors for different radiopharmaceuticals, finding that a lognormal distribution is more suitable for capturing effective half-life distributions. The STP methods showed promise for dosimetry of Lu-177-DOTATATE and kidney dosimetry, but may compromise accuracy for some radiopharmaceuticals.
Because of challenges in performing routine personalized dosimetry in radiopharmaceutical therapies, interest in single-time-point (STP) dosimetry, particularly using only a single SPECT scan, is on the rise. Meanwhile, there are questions about the reliability of STP dosimetry, with limited independent validations. In the present work, we analyzed 2 STP dosimetry methods and evaluated dose errors for several radiopharmaceuticals based on effective half-life distributions. Methods: We first challenged the common assumption that radiopharmaceutical effective half-lives across the population are gaussian-distributed (i.e., follow a normal distribution). Then, dose accuracy was estimated using 2 STP dosimetry methods for a wide range of potential post injection (p.i.) scan time points for different radiopharmaceuticals applied to neuroendocrine tumors and prostate cancer. The accuracy and limitations of each of the STP methods were discussed. Results: A lognormal distribution was more appropriate for capturing effective half-life distributions. The STP framework was promising for dosimetry of Lu-177-DOTATATE and for kidney dosimetry of different radiopharmaceuticals (errors < 30%). Meanwhile, for some radiopharmaceuticals, STP accuracy was compromised (e.g., in bone marrow and tumors for (177)-labeled prostate-specific membrane antigen [PSMA])). The optimal SPECT scanning time for Lu-177-DOTATATE was approximately 72 h p.i., whereas 48 h p.i. was better for Lu-177-PSMA. Conclusion: Simplified STP dosimetry methods may compromise the accuracy of dose estimates, with some exceptions, such as for Lu-177-DOTATATE and for kidney dosimetry in different radiopharmaceuticals. Simplified personalized dosimetry in the clinic continues to be challenging. On the basis of our results, we make suggestions and recommendations for improved personalized dosimetry using simplified imaging schemes.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available