3.8 Proceedings Paper

Model validation of Phase-Induced Amplitude Apodization Complex Mask Coronagraph for LUVOIR-A in vacuum

Publisher

SPIE-INT SOC OPTICAL ENGINEERING
DOI: 10.1117/12.2594901

Keywords

High-Contrast Imaging; Binary Stars; Wavefront Control; WFIRST; Multi-Star Wavefront Control; Super-Nyquist Wavefront Control

Funding

  1. National Aeronautics and Space Administration's Ames Research Center
  2. NASA Strategic Astrophysics Technology - Technology Development for Exoplanet Missions (SAT-TDEM) program at NASA's Science Mission Directorate [NNH16ZDA001N-SAT]

Ask authors/readers for more resources

The PIAACMC design is optimized for the next generation of large space telescopes for imaging habitable exoplanets, achieving attractive theoretical performance. A specific PIAACMC design for LUVOIR-A has been created and tested in vacuum to verify its model and performance.
The Phase-Induced Amplitude Apodization Complex Mask Coronagraph (PIAACMC) is a coronagraph architecture for the next generation of large space telescopes optimized for habitable exoplanet imaging that can achieve attractive theoretical performance with high throughput at small inner working angles (IWA). PIAACMC designs are compatible with large, on-axis, segmented apertures such as the Large UV / Optical/ Infrared A (LUVOIR-A) concept currently being considered by the decadal survey review which would greatly enhance the possibility to achieve statistically significant scientific yields and signal quality for direct imaging exoplanet surveys. A PIAACMC design has been recently created for LUVOIR-A and is currently being tested in vacuum at JPL's High-Contrast Imaging Testbed (HCIT). In this work, we review the theoretical performance of the PIAACMC instrument designed to meet a 1e-9 raw contrast goal in 10% broadband light in a region from 2-8 lambda/D both before and after the wavefront control loop. We use empirical measurements from the vacuum testbed to verify the instrument model and its performance including line-of-sight errors, instrument alignment, and fabricated components. In particular, the model verification includes measured sags of the manufactured PIAA mirrors by NuTek. The CMC mask was manufactured at JPL's Microdevices Laboratory and we include surface profile characterization measurement. We assess the impact on performance of the different manufacturing and alignment errors.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

3.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available