Zero Liquid Discharge and Water Reuse in Recirculating Cooling Towers at Power Facilities: Review and Case Study Analysis

Journal

ACS ES&T ENGINEERING
Volume 2, Issue 3, Pages 508-525

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/acsestengg.1c00377

Keywords

zero liquid discharge; thermoelectric recirculating cooling towers; closed-circuit reverse osmosis; brine concentrator; levelized cost of water

Funding

  1. National Alliance for Water Innovation (NAWI) - U.S. Department of Energy, Energy Efficiency and Renewable Energy Office, Advanced Manufacturing Office [DE-FOA-0001905]
  2. U.S. Department of Energy (DOE) [DE-AC36-08GO28308]

Ask authors/readers for more resources

The implementation of ZLD systems in power facilities can reduce water withdrawals by 18%, but would result in a doubling of the levelized cost of water (LCOW) when using high-recovery RO, and even more when using a brine concentrator. Increasing the evaporation pond area does not reduce system costs, as less water is recovered and more is lost to evaporation. If water availability decreases or competition increases, facilities may be incentivized to maximize water recovery from ZLD systems.
Zero liquid discharge (ZLD) systems installed at power facilities with the primary purpose of meeting water discharge regulations have the added benefit of providing high quality effluent that can be reused in the facility. This paper provides a review of water use in power sector recirculating cooling towers and a baseline assessment of on-site water reuse at natural gas combined cycle (NGCC) power facilities. Two NGCC facilities with reverse-osmosis (RO) or brine-concentrator processes followed by evaporation ponds were selected as case studies; data from these facilities were used to quantify the water, energy, and cost implications of implementing conventional and emerging ZLD technologies. At one case study facility, model results show that implementation of ZLD would reduce water withdrawals by 18%, which is less than savings associated with implementation of dry cooling but comparable to current efforts to reduce water withdrawals by increasing cycles of concentration. Implementation of ZLD using high-recovery RO resulted in a doubling of the levelized cost of water (LCOW). LCOW increased more when a brine concentrator was used. For both case studies, the ZLD system using high-recovery RO required less than 0.1% of a facilitiy's annual electricity generation and the ZLD system using a brine concentrator process required less than 0.8%. Additionally, increasing the evaporation pond area to minimize required ZLD system recovery rates and reduce system electricity costs does not reduce the LCOW. Instead, the LCOW increases because less water is recovered and more water is lost to evaporation. However, if water availability decreases or water competition/cost increases, facilities may be incentivized to maximize water recovery from ZLD systems.