4.6 Article

Automatic Cardiac Structure Contouring for Small Datasets with Cascaded Deep Learning Models

Journal

JOURNAL OF MEDICAL SYSTEMS
Volume 46, Issue 5, Pages -

Publisher

SPRINGER
DOI: 10.1007/s10916-022-01810-6

Keywords

Artificial Intelligence; Heart; X-ray computed tomography; Structure segmentation

Funding

  1. koninklijke nederlandse akademie van wetenschappen (KNAW) [PSA SA BD 01]

Ask authors/readers for more resources

This study developed an automatic cardiac structure segmentation pipeline for use in low-dose non-contrast planning CT. The pipeline achieved good results in contouring the whole heart and ventricles, indicating the feasibility of robust automatic contouring with deep learning methods in local centers with small datasets.
Cardiac structure contouring is a time consuming and tedious manual activity used for radiotherapeutic dose toxicity planning. We developed an automatic cardiac structure segmentation pipeline for use in low-dose non-contrast planning CT based on deep learning algorithms for small datasets. Fifty CT scans were retrospectively selected and the whole heart, ventricles and atria were contoured. A two stage deep learning pipeline was trained on 41 non contrast planning CTs, tuned with 3 CT scans and validated on 6 CT scans. In the first stage, An InceptionResNetV2 network was used to identify the slices that contained cardiac structures. The second stage consisted of three deep learning models trained on the images containing cardiac structures to segment the structures. The three deep learning models predicted the segmentations/contours on axial, coronal and sagittal images and are combined to create the final prediction. The final accuracy of the pipeline was quantified on 6 volumes by calculating the Dice similarity coefficient (DC), 95% Hausdorff distance (95% HD) and volume ratios between predicted and ground truth volumes. Median DC and 95% HD of 0.96, 0.88, 0.92, 0.80 and 0.82, and 1.86, 2.98, 2.02, 6.16 and 6.46 were achieved for the whole heart, right and left ventricle, and right and left atria respectively. The median differences in volume were -4, -1, + 5, -16 and -20% for the whole heart, right and left ventricle, and right and left atria respectively. The automatic contouring pipeline achieves good results for whole heart and ventricles. Robust automatic contouring with deep learning methods seems viable for local centers with small datasets.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available