Mitigation of the Electric and Magnetic Fields of 500-kV Overhead Transmission Lines

Journal

IEEE ACCESS
Volume 10, Issue -, Pages 33900-33908

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/ACCESS.2022.3161932

Keywords

Magnetic fields; Power transmission lines; Wires; Electric fields; Conductors; Mathematical models; Electric potential; Mitigation of the electrical and magnetic fields; numerical methods; biological effects of electromagnetic; overhead power transmission lines

Funding

  1. Department of Electrical Engineering and Automation, School of Electrical Engineering, Aalto University, Espoo, Finland

Ask authors/readers for more resources

The electric and magnetic fields generated by overhead high voltage transmission lines have biological effects on the human body, making it a critical problem for new construction. This article discusses two novel methods for reducing electric and magnetic fields, and validates their effectiveness through a case study.
The electric and magnetic fields of overhead high voltage transmission lines are still a critical problem for new construction because of their biological effects on the human body. This issue has been a subject of scientific interest and public concern for the risk of the electric and magnetic fields on living organisms. Accordingly, the overhead transmission lines are considered a source of such this risk due to their high electric and magnetic fields in the populated areas. Because of the recent concerns that electric besides magnetic fields, generated by overhead transmission lines, electric power researchers have been trying to find effective methods for the mitigation of the electrical and magnetic fields to be in the range of acceptable limits. Researchers have been trying to find transmission line geometries that will reduce these electric and magnetic fields. Therefore, in this article two novel methods of reducing the electric and magnetic fields are discussed, one is to change the position of the center phase to optimize the delta configuration and the other is to use more than two shielding wires with calculating the currents in these wires. The obtained results of the two proposed methods are compared with the electric as well as magnetic fields, and the right-of-way values of the present conventional configuration. Additionally, this article presents a case study carried out on an Egyptian 500 kV high voltage overhead transmission line for the mitigation of magnetic and electric field intensities.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available