4.2 Review

Effective Risk Communications through Personalized Consultations with Pregnant Women and Parents by Radiologic Technologists after the 2011 Fukushima Daiichi Nuclear Disaster

Related references

Note: Only part of the references are listed.
Article Radiology, Nuclear Medicine & Medical Imaging

Radioprotection of eye lens using protective material in neuro cone-beam computed tomography: Estimation of dose reduction rate and image quality

Satoru Kawauchi et al.

Summary: The study evaluated the dose reduction and image quality of different eye lens protection materials in CBCT scans, finding that bismuth shields and lead goggles are suitable protective devices for optimal reduction of lens doses.

PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS (2021)

Article Biology

Evaluation of novel X-ray protective eyewear in reducing the eye dose to interventional radiology physicians

Mime Endo et al.

Summary: The new recommendation by the International Commission on Radiological Protection for an occupational eye dose limit of 20 mSv year(-1) is a drastic reduction from the previous limit of 150 mSv year(-1), highlighting the importance of protecting physicians' eyes from X-ray radiation. A study on novel 0.07 mm Pb glasses showed an average shielding effect of 61.4% for IVR physicians, indicating improved protection and comfort for physicians during procedures. Based on the study results, it is recommended that IVR physicians use these novel 0.07 mm Pb glasses to reduce their radiation exposure.

JOURNAL OF RADIATION RESEARCH (2021)

Article Multidisciplinary Sciences

Total body irradiation causes a chronic decrease in antioxidant levels

Lue Sun et al.

Summary: Exposure to ionizing radiation can lead to chronic oxidative stress and long-term reduction in antioxidant capacity and red blood cell glutathione levels. This study found that chronic reduction in antioxidants may contribute to the pathogenesis of radiation-induced late effects. Interestingly, glutathione and the GSH/GSSG ratio were more sensitive markers of radiation exposure compared to whole-blood antioxidant capacity and complete blood counts.

SCIENTIFIC REPORTS (2021)

Article Medicine, General & Internal

Occupational Radiation Dose to Eye Lenses in CT-Guided Interventions Using MDCT-Fluoroscopy

Yohei Inaba et al.

Summary: This study evaluated radiation doses to physicians and medical staff in CT-guided interventions, finding that the doses to physicians were higher than those to nurses, with significant correlations between physician doses and CT-fluoroscopy mAs. The study highlights the importance of reducing and optimizing radiation dose to medical personnel in CTIs to minimize the risk of radiation-induced injuries.

DIAGNOSTICS (2021)

Article Environmental Sciences

Novel pregnant model phantoms for measurement of foetal radiation dose in x-ray examinations

Yuta Matsunaga et al.

Summary: This study compared novel pregnant model phantoms with handmade phantoms in terms of shape and radiation measurement points, finding that the novel models were more suitable for measuring foetal radiation dose during X-ray examinations. The novel model phantoms improved upon the handmade phantoms in terms of shape and radiation measurement points, providing a more accurate simulation of actual patient sizes and shapes.

JOURNAL OF RADIOLOGICAL PROTECTION (2021)

Article Medicine, General & Internal

Non-Lead Protective Aprons for the Protection of Interventional Radiology Physicians from Radiation Exposure in Clinical Settings: An Initial Study

Mamoru Kato et al.

Summary: Radiation protection/evaluation during interventional radiology poses an important issue. While heavy lead protective aprons may cause orthopedic problems for IVR physicians, lighter non-lead protective aprons demonstrate good shielding effect and comfort in clinical settings. Non-lead protective aprons may be more suitable for providing radiation protection for IVR physicians due to their good performance and comfort.

DIAGNOSTICS (2021)

Review Medicine, General & Internal

Use of Medical Information and Digital Services for Sel-fEmpowerment before, during, and after a Major Disaster

Susumu Fujii et al.

Summary: Disaster response procedures have improved following the Great East Japan Earthquake, with the development of innovative services and accelerated progress in artificial intelligence technology through digital transformation. Balancing the use of data and rational behavior to respond to disasters has become a major challenge, while digital transformation can provide support in normal times and enhance society's disaster resilience.

TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE (2021)

Article Biology

Evaluation of novel X-ray protective eyewear in reducing the eye dose to interventional radiology physicians

Mime Endo et al.

Summary: The International Commission on Radiological Protection has recommended an equivalent dose limit of 20 mSv year(-1) for occupational eye exposure, a significant decrease from the previous limit of 150 mSv year(-1). A study evaluating the shielding effects of novel 0.07 mm Pb glasses showed an improved protection of 61.4% for IVR physicians wearing these glasses during procedures. The lightweight and comfortable glasses were well-received by physicians and are recommended for reducing occupational radiation exposure.

JOURNAL OF RADIATION RESEARCH (2021)

Article Biochemistry & Molecular Biology

Identification of Potential Biomarkers of Radiation Exposure in Blood Cells by Capillary Electrophoresis Time-of-Flight Mass Spectrometry

Lue Sun et al.

INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES (2020)

Article Chemistry, Analytical

Development of Novel Real-Time Radiation Systems Using 4-Channel Sensors

Yohei Inaba et al.

SENSORS (2020)

Article Biology

Radiation eye dose to medical staff during respiratory endoscopy under X-ray fluoroscopy

Yoshihiro Haga et al.

JOURNAL OF RADIATION RESEARCH (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

An initial investigation of a wireless patient radiation dosimeter for use in interventional radiology

Yohei Inaba et al.

RADIOLOGICAL PHYSICS AND TECHNOLOGY (2020)

Article Environmental Sciences

A PHANTOM STUDY TO DETERMINE THE OPTIMAL PLACEMENT OF EYE DOSEMETERS ON INTERVENTIONAL CARDIOLOGY STAFF

H. Ishii et al.

RADIATION PROTECTION DOSIMETRY (2019)

Article Environmental Sciences

OCCUPATIONAL RADIATION EXPOSURE DOSE OF THE EYE IN DEPARTMENT OF CARDIAC ARRHYTHMIA PHYSICIAN

Mamoru Kato et al.

RADIATION PROTECTION DOSIMETRY (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Diagnostic reference levels and achievable doses for common computed tomography examinations: Results from the Japanese nationwide dose survey

Yuta Matsunaga et al.

BRITISH JOURNAL OF RADIOLOGY (2019)

Article Biology

New real-time patient radiation dosimeter for use in radiofrequency catheter ablation

Mamoru Kato et al.

JOURNAL OF RADIATION RESEARCH (2019)

Article Environmental Sciences

OCCUPATIONAL RADIATION EXPOSURE OF THE EYE IN NEUROVASCULAR INTERVENTIONAL PHYSICIAN

Mamoru Kato et al.

RADIATION PROTECTION DOSIMETRY (2019)

Article Environmental Sciences

PATIENT EXPOSURE DURING PLAIN RADIOGRAPHY AND MAMMOGRAPHY IN JAPAN IN 1974-2014

Yuta Matsunaga et al.

RADIATION PROTECTION DOSIMETRY (2017)

Article Medicine, General & Internal

Decontamination Reduces Radiation Anxiety and Improves Subjective Well-Being after the Fukushima Accident

Michio Murakami et al.

TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE (2017)

Article Multidisciplinary Sciences

Occupational eye dose in interventional cardiology procedures

Yoshihiro Haga et al.

SCIENTIFIC REPORTS (2017)

Review Public, Environmental & Occupational Health

Communicating With Residents About Risks Following the Fukushima Nuclear Accident

Michio Murakami et al.

ASIA-PACIFIC JOURNAL OF PUBLIC HEALTH (2017)

Article Cardiac & Cardiovascular Systems

Need for radiation safety education for interventional cardiology staff, especially nurses

Yoshiaki Morishima et al.

ACTA CARDIOLOGICA (2016)

Article Radiology, Nuclear Medicine & Medical Imaging

Occupational Dose in Interventional Radiology Procedures

Koichi Chida et al.

AMERICAN JOURNAL OF ROENTGENOLOGY (2013)

Editorial Material Medicine, General & Internal

Revisiting the March 11, 2011 Earthquake and Tsunami: Resilience and Restoration

Shigeki Shibahara

TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE (2012)

Editorial Material Medicine, General & Internal

The 2011 Tohoku Earthquake and Devastating Tsunami

Shigeki Shibahara

TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE (2011)

Article Radiology, Nuclear Medicine & Medical Imaging

Comparison of dose at an interventional reference point between the displayed estimated value and measured value

Koichi Chida et al.

RADIOLOGICAL PHYSICS AND TECHNOLOGY (2011)

Article Radiology, Nuclear Medicine & Medical Imaging

Radiation Dose to the Pediatric Cardiac Catheterization and Intervention Patient

Koichi Chida et al.

AMERICAN JOURNAL OF ROENTGENOLOGY (2010)

Article Radiology, Nuclear Medicine & Medical Imaging

Evaluating the performance of a MOSFET dosimeter at diagnostic X-ray energies for interventional radiology

Koichi Chida et al.

RADIOLOGICAL PHYSICS AND TECHNOLOGY (2009)

Article Radiology, Nuclear Medicine & Medical Imaging

Relationship between fluoroscopic time, dose-area product, body weight, and maximum radiation skin dose in cardiac interventional procedures

K Chida et al.

AMERICAN JOURNAL OF ROENTGENOLOGY (2006)