4.6 Article

In vitro electrochemical measurement of serotonin release in the human jejunum mucosa using a diamond microelectrode

Journal

ANALYST
Volume 147, Issue 11, Pages 2523-2532

Publisher

ROYAL SOC CHEMISTRY
DOI: 10.1039/d2an00487a

Keywords

-

Funding

  1. National Institutes of Health (USA) [R01DK094932, T32GM092715]
  2. [CHE-0911383]

Ask authors/readers for more resources

This study reports the use of a boron-doped diamond microelectrode (DME) to record oxidation currents associated with the release of serotonin from enterochromaffin cells in the human intestinal mucosa. The results demonstrate the stable and reproducible detection of serotonin by the DME in the complex environment of human tissue. The presence of fluoxetine, a selective serotonin reuptake inhibitor, resulted in increased oxidation currents, indicating serotonin as the main contributor to the detected amperometric current.
We report herein on the use of a boron-doped diamond microelectrode (DME) to record oxidation currents in vitro associated with the release of serotonin from enterochromaffin cells in the epithelium of the human intestinal mucosa. Continuous amperometric measurements were made as a function of distance (ln current vs. distance) from the tissue surface in human jejunum specimens. The results demonstrate the capabilities of the DME for the stable and reproducible detection of serotonin in the complex environment of the human tissue. Serotonin release was evoked by the shearing force of a continuously flowing Krebs buffer solution at 36 degrees C with the tissue pinned down in a flow bath. Reproducible currents with distance were recorded for serotonin oxidation. Increased oxidation currents were observed in the presence of the selective serotonin reuptake inhibitor, fluoxetine, indicating that a significant fraction of the amperometric current recorded is attributable to serotonin oxidation. The nominal reciprocal slope, |slope(-1)|, of the ln current vs. distance plots increased from 270 +/- 25 mu m(-1) in Krebs buffer (N = 3) to 471 +/- 65 mu m(-1) during fluoxetine addition (N = 3), reflective of a reduced rate of reuptake in the presence of the SERT antagonist. The paper reports on the characterization of the diamond microelectrodes and the in vitro electrochemical measurement data.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available