4.7 Article

Experimental and numerical investigation on U-shaped tube liquid-separation plate condenser

Journal

APPLIED THERMAL ENGINEERING
Volume 211, Issue -, Pages -

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2022.118518

Keywords

Liquid-separation; Plate condenser; Thermal transfer performance; Plate heat exchanger

Funding

  1. Shanghai Nanhua Heat exchanger Manufacturing Co., LTD
  2. Nanjing Tongcheng Energy saving and Environmental Protection Equipment Research Institute

Ask authors/readers for more resources

A novel U-shaped tube liquid-separation plate condenser (LPC) was designed and its heat transfer capacity was increased by 1 to 1.5 times compared to the ordinary plate condenser. The heat transfer coefficient of the LPC was improved up to 31.2%. The structure optimization of the LPC resulted in a short-to-long axis ratio of 0.6, a 2-stages liquid-separation, and a liquid-separation position at 3/4.
Plate heat exchanger is a kind of widely used efficient energy exchange equipment, which has the advantages of high heat transfer coefficient, compact structure, easy cleaning and maintenance. However, the accumulation of condensate forming liquid film weakens heat transfer effect of ordinary plate condenser (OPC). Effectiveness of liquid-separation condensation on improving heat transfer effect has been confirmed in previous research, but the design of liquid-separation unit may cause insufficient vapor-liquid separation thereby hindering the improvement of heat exchange effect. In this paper, a novel U-shaped tube liquid-separation plate condenser (LPC) is firstly designed. Moreover, this research mainly focused on investigating the feasibility of U-shaped liquid-separation unit, the universal applicability of the LPC and structure optimization of the LPC. Experimental results indicate that the heat transfer capacity of the LPC is increased 1 to 1.5 times than that of the OPC and the heat transfer coefficient of the LPC could be improved up to 31.2%, heat transfer coefficient improving rate of the LPC is in the range of 20% to 36% under different cooling methods. Furthermore, numerical results on structure optimization of the LPC are the short-to-long axis ratio at 0.6, the 2-stages liquid-separation and the liquid-separation position at 3/4, respectively. This work has potential for practical application.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available