4.7 Article

Research of the Response Rate Variation for the Extinguishant Detection Technique Based on the Differential Pressure Principle

Journal

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TIM.2022.3178502

Keywords

Sensors; Temperature sensors; Temperature measurement; Gas detectors; Dispersion; Safety; Semiconductor device measurement; Concentration measurement; differential pressure principle; gaseous extinguishing agent; response rate

Funding

  1. Natural Science Foundation of Shandong Province [ZR2020QE134]
  2. Key Projects of Natural Science Foundation of Anhui Province [2008085UD07]

Ask authors/readers for more resources

The purpose of this study is to explore the variation mechanism of the response rate for the extinguishant detection technique based on the differential pressure principle. The effects of the sampling pipe, sensing structure, and operating temperature on the response rate were analyzed, and a theoretical model was established based on gas dispersion behavior. The results show that the response/recovery time is greatly influenced by these factors, and increasing the length and inner diameter of the sampling pipe can significantly increase the response/recovery time. Adjusting certain parameters of the sensing structure can have opposite effects. Moreover, increasing the operating temperature can decrease the response/recovery time to some extent.
The intent of this work is to explore the variation mechanism of the response rate for the extinguishant detection technique based on the differential pressure principle, which is an aspirating concentration detection technique and quite suitable for extinguishant detection. The effects of the sampling pipe, sensing structure, and operating temperature on the response rate were analyzed, and the theoretical model was established by analyzing the gas dispersion behavior. It is found that the response/recovery time is greatly affected by the above factors, which can change from 0.068/0.088 to 0.960/1.01 s. Results show that with the increase of the length and inner diameter of the sampling pipe, the response/recovery time rapidly increases. For the sensing structure, the increase of the external diameter of the vascular bundles will increase the response/recovery time, and the increase of the throat diameter of the critical flow nozzle will greatly decrease the response/recovery time. The increase of the operating temperature can decrease the response/recovery time with limited improving effect. The research results in this article can provide suggestions for the design of sensor.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available