4.5 Article

Evaluating the effectiveness of abbreviated breast MRI (abMRI) interpretation training for mammogram readers: a multi-centre study assessing diagnostic performance, using an enriched dataset

Journal

BREAST CANCER RESEARCH
Volume 24, Issue 1, Pages -

Publisher

BMC
DOI: 10.1186/s13058-022-01549-5

Keywords

Breast cancer; Abbreviated breast MRI; FAST MRI; Education; Training; Diagnostic accuracy

Categories

Funding

  1. National Institute for Health Research [PB-PG-1217-20008]
  2. NIHR Career Development Fellowship [CDF -2016-09-018]
  3. National Institutes of Health Research (NIHR) [PB-PG-1217-20008] Funding Source: National Institutes of Health Research (NIHR)

Ask authors/readers for more resources

The study aimed to examine the diagnostic accuracy of mammogram readers to interpret abbreviated breast MRI (abMRI) after a single day of training and compare the performance between experienced and inexperienced readers of full-protocol breast MRI (fpMRI). The results showed that inexperienced readers had lower diagnostic accuracy compared to experienced readers, suggesting the need for additional training.
Background Abbreviated breast MRI (abMRI) is being introduced in breast screening trials and clinical practice, particularly for women with dense breasts. Upscaling abMRI provision requires the workforce of mammogram readers to learn to effectively interpret abMRI. The purpose of this study was to examine the diagnostic accuracy of mammogram readers to interpret abMRI after a single day of standardised small-group training and to compare diagnostic performance of mammogram readers experienced in full-protocol breast MRI (fpMRI) interpretation (Group 1) with that of those without fpMRI interpretation experience (Group 2). Methods Mammogram readers were recruited from six NHS Breast Screening Programme sites. Small-group hands-on workstation training was provided, with subsequent prospective, independent, blinded interpretation of an enriched dataset with known outcome. A simplified form of abMRI (first post-contrast subtracted images (FAST MRI), displayed as maximum-intensity projection (MIP) and subtracted slice stack) was used. Per-breast and per-lesion diagnostic accuracy analysis was undertaken, with comparison across groups, and double-reading simulation of a consecutive screening subset. Results 37 readers (Group 1: 17, Group 2: 20) completed the reading task of 125 scans (250 breasts) (total = 9250 reads). Overall sensitivity was 86% (95% confidence interval (CI) 84-87%; 1776/2072) and specificity 86% (95%CI 85-86%; 6140/7178). Group 1 showed significantly higher sensitivity (843/952; 89%; 95%CI 86-91%) and higher specificity (2957/3298; 90%; 95%CI 89-91%) than Group 2 (sensitivity = 83%; 95%CI 81-85% (933/1120) p < 0.0001; specificity = 82%; 95%CI 81-83% (3183/3880) p < 0.0001). Inter-reader agreement was higher for Group 1 (kappa = 0.73; 95%CI 0.68-0.79) than for Group 2 (kappa = 0.51; 95%CI 0.45-0.56). Specificity improved for Group 2, from the first 55 cases (81%) to the remaining 70 (83%) (p = 0.02) but not for Group 1 (90-89% p = 0.44), whereas sensitivity remained consistent for both Group 1 (88-89%) and Group 2 (83-84%). Conclusions Single-day abMRI interpretation training for mammogram readers achieved an overall diagnostic performance within benchmarks published for fpMRI but was insufficient for diagnostic accuracy of mammogram readers new to breast MRI to match that of experienced fpMRI readers. Novice MRI reader performance improved during the reading task, suggesting that additional training could further narrow this performance gap.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available