3.9 Article

Electrochemical Capillary Driven Immunoassay for Detection of SARS-CoV-2

Related references

Note: Only part of the references are listed.
Article Immunology

Impaired detection of omicron by SARS-CoV-2 rapid antigen tests

Andreas Osterman et al.

Summary: This study evaluated the performance of nine SARS-CoV-2 rapid antigen tests (RATs) in a single-centre laboratory study. The results showed that higher virus loads were required for omicron-containing samples compared to delta-containing samples in order to test positive in these point-of-care tests. However, testing of expanded virus stocks suggested a comparable RAT sensitivity for both omicron and delta variants, questioning the predictive value of in vitro studies for clinical performance. Given the importance of RATs in national testing strategies during the omicron wave, awareness must be increased for the reduced detection rate of omicron infections by RATs and a short list of suitable RATs should be disclosed.

MEDICAL MICROBIOLOGY AND IMMUNOLOGY (2022)

Article Chemistry, Analytical

Molecularly imprinted polymer based electrochemical sensor for quantitative detection of SARS-CoV-2 spike protein

Akinrinade George Ayankojo et al.

Summary: The study presents an electrochemical sensor based on a molecularly imprinted polymer receptor for quantitatively detecting the S1 subunit of the spike protein of SARS-CoV-2. It has a quick response time and low detection limit, showing promise as a point-of-care testing platform for early diagnosis of COVID-19.

SENSORS AND ACTUATORS B-CHEMICAL (2022)

Article Materials Science, Multidisciplinary

3D-Printed SARS-CoV-2 RNA Genosensing Microfluidic System

Agustin G. Crevillen et al.

Summary: Additive manufacturing technology, also known as 3D printing technology, has broad applications from nanosensors fabrication to 3D printing of buildings. Combining with real-time screening, the use of 3D printing for fast sensor development is significant during the COVID-19 pandemic.

ADVANCED MATERIALS TECHNOLOGIES (2022)

Article Chemistry, Analytical

Electrochemical Immunoassay for the Detection of SARS-CoV-2 Nucleocapsid Protein in Nasopharyngeal Samples

Isabelle C. Samper et al.

Summary: A highly sensitive electrochemical immunoassay has been developed for quantitatively detecting the presence of SARS-CoV-2 virus in patient nasopharyngeal samples. The assay demonstrates high specificity and sensitivity, meeting the criteria for POC COVID-19 diagnostic tests set by the World Health Organization.

ANALYTICAL CHEMISTRY (2022)

Article Multidisciplinary Sciences

Detection and quantification of infectious severe acute respiratory coronavirus-2 in diverse clinical and environmental samples

Yi-Chan Lin et al.

Summary: This study explored the potential modes of SARS-CoV-2 transmission and found that large respiratory droplets and contact (direct and indirect) are important modes of transmission. The presence of infectious virus in clinical and environmental samples correlated with time since symptom onset and the ability to yield plaques in culture.

SCIENTIFIC REPORTS (2022)

Article Materials Science, Multidisciplinary

Collective behavior of magnetic microrobots through immuno-sandwich assay: On-the-fly COVID-19 sensing

Carmen C. Mayorga-Martinez et al.

Summary: Mobile self-propelled micro/nanorobots enhance the sensitivity of biosensing systems by identifying and isolating different biotargets. In this study, magnetic microrobots that self-assemble through immuno-sandwich assay are presented as a mobile platform for detecting SARS-CoV-2 virus particles.

APPLIED MATERIALS TODAY (2022)

Review Biochemical Research Methods

Review of analytical performance of COVID-19 detection methods

Basant Giri et al.

Summary: In the recent COVID-19 pandemic, various diagnostic methods have been developed for detecting the virus, with factors such as throughput, infrastructure requirements, and analytical performance varying between methods. Selecting a reliable and rapid diagnostic method is crucial for making appropriate decisions and implementing effective public health interventions.

ANALYTICAL AND BIOANALYTICAL CHEMISTRY (2021)

Article Chemistry, Analytical

Clinical Application of the Novel Cell-Based Biosensor for the Ultra-Rapid Detection of the SARS-CoV-2 S1 Spike Protein Antigen: A Practical Approach

Sophie Mavrikou et al.

Summary: The new biosensor demonstrated rapid, high sensitivity and selectivity in detecting the SARS-CoV-2 virus in clinical samples, showing potential for early, routine mass screening on a scale that has not yet been achieved.

BIOSENSORS-BASEL (2021)

Review Virology

Microfluidic devices for detection ofRNAviruses

Arefeh Basiri et al.

Summary: Finding a rapid, easy-to-use, and cost-effective diagnostic method is crucial for controlling the Covid-19 outbreak. Microfluidic systems show promise as an alternative method for detecting viral RNA with faster, cheaper, and higher sensitivity capabilities.

REVIEWS IN MEDICAL VIROLOGY (2021)

Article Genetics & Heredity

Analysis and comparison of genetic variants and mutations of the novel coronavirus SARS-CoV-2

Zaid Almubaid et al.

Summary: This study analyzed and compared genetic variants of approximately 1200 genomes of SARS-CoV-2 virus sampled between January and September 2020, identifying non-random mutations and adaptive changes in the virus. The findings suggest potential drug targets in the relatively conserved coding region of NSP13 protein, with implications for COVID-19 treatment and virus evolution.

GENE REPORTS (2021)

Review Biotechnology & Applied Microbiology

Detection technologies and recent developments in the diagnosis of COVID-19 infection

Praveen Rai et al.

Summary: COVID-19 is a disease caused by SARS-CoV-2 that has spread globally, requiring collaborative efforts for accurate diagnosis and prevention. While RT-qPCR detection is considered the gold standard for early virus detection, challenges such as technical complexity and limited applicability have led to the development of portable POC tests.

APPLIED MICROBIOLOGY AND BIOTECHNOLOGY (2021)

Article Biophysics

Magnetic beads combined with carbon black -based screen-printed electrodes for COVID-19: A reliable and miniaturized electrochemical immunosensor for SARS-CoV-2 detection in saliva

Laura Fabiani et al.

Summary: The study developed an electrochemical immunoassay for rapid and smart detection of SARS-CoV-2 coronavirus in saliva, with high sensitivity, rapid analysis (30 min), miniaturization, portability, and ease of use.

BIOSENSORS & BIOELECTRONICS (2021)

Article Engineering, Environmental

3D-Printed COVID-19 immunosensors with electronic readout

Jose Munoz et al.

Summary: This study presents a method for producing a 3D-printed COVID-19 immunosensor with electronic readout using surface engineering for biofunctionalization. The system exhibits promising electroanalytical capabilities in different samples, with low cost and trace level detection limit.

CHEMICAL ENGINEERING JOURNAL (2021)

Review Chemistry, Analytical

COVID-19: A challenge for electrochemical biosensors

Jiri Kudr et al.

Summary: The COVID-19 pandemic has created a demand for improvement and development of diagnostic methods, with electrochemical biosensors showing promise as rapid, low-cost, and user-friendly tools. This critical review outlines the molecular properties of SARS-CoV-2 and discusses the advantages and drawbacks of conventional diagnostic methods while highlighting the potential of electrochemical biosensors. Future perspectives on viral electrochemical biosensor development are briefly mentioned.

TRAC-TRENDS IN ANALYTICAL CHEMISTRY (2021)

Review Chemistry, Analytical

Pathogen detection with electrochemical biosensors: Advantages, challenges and future perspectives

Huseyin Oguzhan Kaya et al.

Summary: Detection of pathogens, such as bacteria and viruses, remains a challenge in analytical medicine, but utilizing electrochemical methods can achieve rapid, inexpensive, specific, and sensitive detection. Electrochemical biosensors have made significant advances in the detection of bacteria and viruses, showing a wide range of potential applications.

JOURNAL OF ELECTROANALYTICAL CHEMISTRY (2021)

Article Infectious Diseases

Scaling up COVID-19 rapid antigen tests: promises and challenges

Rosanna W. Peeling et al.

Summary: WHO recommends antigen-detection rapid diagnostic tests (Ag-RDTs) with at least 80% sensitivity and 97% specificity for patients with symptoms consistent with COVID-19. Ag-RDTs may show high false negative rates after the acute phase, suggesting the need for a combination of molecular and serological tests. In low prevalence settings and situations where infection needs to be ruled out, Ag-RDTs with high negative predictive values can be used confidently, but high false positive rates in low prevalence areas require further confirmation.

LANCET INFECTIOUS DISEASES (2021)

Article Chemistry, Multidisciplinary

Rapid SARS-CoV-2 Spike Protein Detection by Carbon Nanotube-Based Near-Infrared Nanosensors

Rebecca L. Pinals et al.

Summary: Developing tools for rapid and accessible diagnosis of actively infected individuals, a SWCNT-based sensor functionalized with ACE2 was introduced for rapid SARS-CoV-2 detection. The sensor exhibited a robust 2-fold fluorescence increase within 90 minutes of exposure to the virus spike protein, showing potential for practical application in diagnostic settings. The study demonstrated the stability and sensing capacity of the ACE2-SWCNT nanosensors in various mediums, highlighting their potential as a rapid optical tool for COVID-19 detection.

NANO LETTERS (2021)

Review Virology

A Comparative Systematic Review of COVID-19 and Influenza

Molka Osman et al.

Summary: This study found significant differences between COVID-19 and influenza patients in clinical features, laboratory and radiological findings. COVID-19 patients were more likely to exhibit neurologic symptoms and diarrhea, and they were also more frequently transferred to intensive care units.

VIRUSES-BASEL (2021)

Article Chemistry, Multidisciplinary

Electrochemical Capillary-Flow Immunoassay for Detecting Anti-SARS-CoV-2 Nucleocapsid Protein Antibodies at the Point of Care

Isabelle C. Samper et al.

Summary: A novel low-cost electrochemical capillary-flow device was developed for rapid detection of SARS-CoV-2 antibodies within 20 minutes without the need for sample preparation. The device integrates blood-filtration membrane for plasma extraction and automated steps of an ELISA, providing accurate and reliable results for point-of-care testing. The novelty lies in the integration of sensitive electrochemical detection with capillary-flow immunoassay, showing potential for aiding the diagnosis of infectious diseases at the point of care.

ACS SENSORS (2021)

Article Multidisciplinary Sciences

Limit of detection in different matrices of 19 commercially available rapid antigen tests for the detection of SARS-CoV-2

Ana Cubas-Atienzar et al.

Summary: In this study, an independent evaluation was conducted on the limit of detection (LOD) of 19 marketed Ag-RDTs, revealing that most tests performed well with direct culture supernatant but showed decreased sensitivity in Amies media. Additionally, after 7 days of storage at -80 degrees C, some tests exhibited reduced efficiency on stored dilutions of SARS-CoV-2.

SCIENTIFIC REPORTS (2021)

Article Chemistry, Multidisciplinary

Rapid and Efficient Detection of the SARS-CoV-2 Spike Protein Using an Electrochemical Aptamer-Based Sensor

Andrea Idili et al.

Summary: This study developed an electrochemical aptamer-based sensor for the rapid, reagentless, and quantitative measurement of the SARS-CoV-2 spike protein, demonstrating its sensitivity and specificity in biological fluids and highlighting its clinical potential for rapid detection.

ACS SENSORS (2021)

Article Microbiology

Optimization and Stability Testing of Four Commercially Available Dried Blood Spot Devices for Estimating Measles and Rubella IgG Antibodies

Ojas Kaduskar et al.

Summary: Blood collection using dried blood spots (DBS) offers a convenient alternative to venipuncture, but additional processing can lead to variability in results. Testing showed that some DBS devices had comparable antibody concentrations with sera, and the HemaSpot HF device demonstrated good stability at ambient temperature.

MSPHERE (2021)

Article Microbiology

Anti-Spike Protein Assays to Determine SARS-CoV-2 Antibody Levels: a Head-to-Head Comparison of Five Quantitative Assays

Thomas Perkmann et al.

Summary: Reliable quantification of the antibody response to SARS-CoV-2 is crucial for identifying possible vaccine failure and estimating protection time. Despite good overall agreement, the performance of five antibody quantification assays showed differences that highlight the need for further standardization of SARS-CoV-2 serology.

MICROBIOLOGY SPECTRUM (2021)

Article Infectious Diseases

Comparison of seven commercial SARS-CoV-2 rapid point-of-care antigen tests: a single-centre laboratory evaluation study

Victor M. Corman et al.

Summary: This study compared the analytical sensitivity and specificity of seven commercially available antigen point-of-care test devices, showing that most devices have sensitivity overlapping with SARS-CoV-2 viral loads typically observed during the first week of symptoms, marking the infectious period in most patients. Antigen point-of-care tests with detection limits approximating virus concentrations at which patients are infectious may streamline decision-making in healthcare and public health.

LANCET MICROBE (2021)

Review Public, Environmental & Occupational Health

Review of infective dose, routes of transmission and outcome of COVID-19 caused by the SARS-COV-2: comparison with other respiratory viruses

Sedighe Karimzadeh et al.

Summary: A rapid review of the literature on SARS-CoV-2 viral dynamics revealed limited understanding of infective dose, transmission, and routes of exposure in human studies. Increased viral load did not necessarily correlate with disease severity. Aerosol transmission may raise the risk of more severe respiratory complications.

EPIDEMIOLOGY AND INFECTION (2021)

Review Biochemistry & Molecular Biology

Protein-based lateral flow assays for COVID-19 detection

Farbod Mahmoudinobar et al.

Summary: In order to combat the spread of COVID-19, rapid diagnostic innovations based on protein-protein interactions have been developed, particularly antigen tests using the LFA test platform. Despite the convenience and lower cost of these tests, they have faced criticism for lower sensitivity, prompting recent efforts to create rapid LFA tests with higher limit of detection.

PROTEIN ENGINEERING DESIGN & SELECTION (2021)

Article Chemistry, Analytical

Flow control in a laminate capillary-driven microfluidic device

Ilhoon Jang et al.

Summary: Capillary-driven microfluidic devices made from paper and polyester film are commonly used due to their low cost and lack of external pumps. However, controlling flow in these devices can be challenging due to the sole reliance on capillary forces. This study introduces new flow control methods, such as push and burst valve systems, for increased functionality in laminate capillary-driven microfluidic devices. These methods enable precise control of flow direction, concentration, and velocity, ultimately offering new design possibilities for on-site analysis in various fields.

ANALYST (2021)

Article Virology

Changes in SARS-CoV-2 Spike versus Nucleoprotein Antibody Responses Impact the Estimates of Infections in Population-Based Seroprevalence Studies

Craig Fenwick et al.

Summary: In this study, antibody responses to SARS-CoV-2 were evaluated in acute and postinfection subjects. The results show that responses against viral S and N proteins were equally sensitive in acute phase, but N responses decreased in postinfection phase while S responses persisted. The most sensitive assay used the native S protein trimer, suggesting its importance in estimating SARS-CoV-2 infections and assessing vaccine-induced responses.

JOURNAL OF VIROLOGY (2021)

Review Biotechnology & Applied Microbiology

Paper-based point-of-care immunoassays: Recent advances and emerging trends

Fei Li et al.

BIOTECHNOLOGY ADVANCES (2020)

Article Biology

SARS-CoV-2 (COVID-19) by the numbers

Yinon M. Bar-On et al.

ELIFE (2020)

Article Chemistry, Multidisciplinary

Assay Techniques and Test Development for COVID-19 Diagnosis

Linda J. Carter et al.

ACS CENTRAL SCIENCE (2020)

Article Chemistry, Analytical

Fabrication of microwell plates and microfluidic devices in polyester films using a cutting printer

Nikaele S. Moreira et al.

ANALYTICA CHIMICA ACTA (2020)

Article Chemistry, Multidisciplinary

Pump-Free Microfluidic Rapid Mixer Combined with a Paper-Based Channel

Ilhoon Jang et al.

ACS SENSORS (2020)

Article Virology

Comparison of seven commercial RT-PCR diagnostic kits for COVID-19

Puck B. van Kasteren et al.

JOURNAL OF CLINICAL VIROLOGY (2020)

Review Biophysics

Detection of COVID-19: A review of the current literature and future perspectives

Tianxing Ji et al.

BIOSENSORS & BIOELECTRONICS (2020)

Article Pharmacology & Pharmacy

COVID-19 Clinical Diagnostics and Testing Technology

Cindy H. Chau et al.

PHARMACOTHERAPY (2020)

Article Cell Biology

COVID-19 diagnostics in context

Ralph Weissleder et al.

SCIENCE TRANSLATIONAL MEDICINE (2020)

Article Chemistry, Analytical

Viscosity measurements utilizing a fast-fl ow micro fl uidic paper -based device

Ilhoon Jang et al.

SENSORS AND ACTUATORS B-CHEMICAL (2020)

Article Virology

Growth, detection, quantification, and inactivation of SARS-CoV-2

James Brett Case et al.

VIROLOGY (2020)

Article Chemistry, Analytical

Design considerations for reducing sample loss in microfluidic paper-based analytical devices

Michael P. Nguyen et al.

ANALYTICA CHIMICA ACTA (2018)

Review Chemistry, Multidisciplinary

Turning the Page: Advancing Paper-Based Microfluidics for Broad Diagnostic Application

Max M. Gong et al.

CHEMICAL REVIEWS (2017)

Review Chemistry, Multidisciplinary

Flow control in paper-based microfluidic device for automatic multistep assays: A focused minireview

Seong-Geun Jeong et al.

KOREAN JOURNAL OF CHEMICAL ENGINEERING (2016)

Review Chemistry, Analytical

Lateral-flow technology: From visual to instrumental

Wing Cheung Mak et al.

TRAC-TRENDS IN ANALYTICAL CHEMISTRY (2016)

Article Engineering, Biomedical

A Microfluidic Paper-Based Origami Nanobiosensor for Label-Free, Ultrasensitive Immunoassays

Xiao Li et al.

ADVANCED HEALTHCARE MATERIALS (2016)

Article Biochemical Research Methods

Engineering fluidic delays in paper-based devices using laser direct-writing

P. J. W. He et al.

LAB ON A CHIP (2015)

Article Chemistry, Analytical

Long-term dry storage of an enzyme-based reagent system for ELISA in point-of-care devices

Sujatha Ramachandran et al.

ANALYST (2014)

Article Chemistry, Analytical

Programming Fluid Transport in Paper-Based Microfluidic Devices Using Razor-Crafted Open Channels

Dimosthenis L. Giokas et al.

ANALYTICAL CHEMISTRY (2014)

Review Chemistry, Analytical

Screen-printed electrodes for biosensing: a review (2008-2013)

Zahra Taleat et al.

MICROCHIMICA ACTA (2014)

Review Biochemical Research Methods

Paper-based microfluidic point-of-care diagnostic devices

Ali Kemal Yetisen et al.

LAB ON A CHIP (2013)

Article Biochemical Research Methods

A fluidic diode, valves, and a sequential-loading circuit fabricated on layered paper

Hong Chen et al.

LAB ON A CHIP (2012)

Review Chemistry, Multidisciplinary

Microfluidic Devices for Bioapplications

Leslie Y. Yeo et al.

SMALL (2011)

Article Virology

Infectious alphavirus production from a simple plasmid transfection

J. Jordan Steel et al.

VIROLOGY JOURNAL (2011)

Article Biochemical Research Methods

Controlled reagent transport in disposable 2D paper networks

Elain Fu et al.

LAB ON A CHIP (2010)

Article Biochemical Research Methods

Enzyme linked immunosorbent assay on a microchip with electrochemical detection

JS Rossier et al.

LAB ON A CHIP (2001)