3.8 Article

Monitoring of phosphorus discharge in a sewage treatment plant with a phosphate automated analyzer

Journal

ENVIRONMENTAL SCIENCE-ADVANCES
Volume 1, Issue 4, Pages 483-490

Publisher

ROYAL SOC CHEMISTRY
DOI: 10.1039/d2va00062h

Keywords

-

Funding

  1. This Research was supported by Ramp
  2. D Center for Green Patrol Technologies through the Ramp
  3. D for Global Top Environmental Technologies funded by Ministry of Environment (MOE), Republic of Korea, NTIS No. 1485016089. [1485016089]
  4. Ramp
  5. D Center for Green Patrol Technologies through the Ramp
  6. D - Ministry of Environment (MOE), Republic of Korea

Ask authors/readers for more resources

This study optimized the removal of phosphate in a wastewater treatment plant using a phosphate automated analyzer in the final discharge effluent.
The removal of phosphorus in the sewage treatment plant is commonly done with precipitation with ferric iron in the form of ferric chloride. Ferric iron is added to the sludge recycling stream to assure a good mixing with the wastewater in the biological reactor. The precipitated phosphate is removed in the secondary settling tanks with the excess of biological sludge. This study installed and optimized the operation of a phosphate automated analyzer in the wastewater treatment plant with the objective to use the phosphate concentrations to adjust the dosing of ferric chloride and minimize its consumption. The study tested three sampling points for the phosphate automated analyzer: the sludge recycling stream to the biological reactors, the outlet of the biological reactor and the final discharge effluent. The objective is to identify the most stable sampling point to determine the necessary amount of ferric chloride to comply with the phosphorus legal limit in the outlet stream discharge into the sea. This study concluded that the phosphate analysis in the final discharge effluent is the best location for a stable and reliable phosphate determination. Furthermore, the phosphate concentration in the final discharge effluent is proportional (97-98%) to the total phosphorus concentration, so the phosphate analyzer can be used for the monitoring of phosphorus assuring the compliance with the legal discharge limit. This study optimized the removal of phosphate in a wastewater treatment plant using a phosphate automated analyzer in the final discharge effluent.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

3.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available