4.6 Article

Overoxidized polypyrrole/overoxidized poly(3,4-ethylenedioxythiophene)/graphene quantum dots-chitosan as enhanced electrochemical sensing platform for luteolin determination in peanut shells

Journal

NEW JOURNAL OF CHEMISTRY
Volume 46, Issue 43, Pages 20610-20622

Publisher

ROYAL SOC CHEMISTRY
DOI: 10.1039/d2nj03738f

Keywords

-

Funding

  1. Key Research and Development (R&D) Projects of Shanxi Province [201903D121114]
  2. Scientific and Technological Innovation Programs of Higher Education Institutions in Shanxi [2020L0667, 2020L0662]

Ask authors/readers for more resources

In this study, a novel electrochemical sensor was constructed for the accurate determination of luteolin in peanut shells. The sensor exhibited good anti-interference ability, repeatability, and stability. The linear detection range was 0.01 to 10.0 μM with a limit of detection of 7.5 nM. The constructed sensor showed accurate detection of luteolin in peanut shells.
A novel electrochemical sensor was constructed based on an overoxidized polypyrrole/overoxidized poly(3,4-ethylenedioxythiophene)/graphene quantum dots-chitosan composite film modified glass carbon electrode (oPPy/oPEDOT/GQDs-CS/GCE), for the accurate determination of luteolin in peanut shells. The oPPy/oPEDOT/GQDs-CS/GCE was prepared using layer-by-layer assembly methods. After incubation in NaOH-EtOH solution, the current of luteolin on the composite electrode increased from 0 to similar to 30 mu A, the R-ct value decreased by similar to 80 fold, and the specific surface area (A) increased by similar to 7 fold. Based on a three-level four-factor Box-Behnken design (BBD), the optimal preparation conditions for the composite electrode were as follows: a mass ratio of CS to GQDs of 5, a polymerization cycle number for EDOT of 4, a polymerization cycle number for Py of 4, with the peak current increased to 43.21 mu A (RSD = 3.51%, n = 3). A morphology with multi-channels and grooves was observed on the surface of the incubated composite film via SEM analysis. The additional -C-N- and -SO/-SO2 groups formed were observed by XPS and FTIR analysis. The electrochemical sensor constructed exhibited good anti-interference ability, repeatability, and stability. The linear detection range recorded by the current responses of the composite electrode to luteolin was 0.01 to 10.0 mu M (R-2 = 0.991) and the limit of detection was 7.5 nM (S/N = 3). The observed content of luteolin in peanut shells was 0.769%, which was close to the results obtained from High Performance Liquid Chromatography (HPLC) analysis (0.808%). This agreement indicated that the constructed electrochemical sensor based on oPPy/oPE-DOT/GQDS-CS/GCE was capable of accurate detection of luteolin in peanut shells.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available