4.6 Article

Spectral filtering method for improvement of detection accuracy of Mg, Cu, Mn and Cr elements in aluminum alloys using femtosecond LIBS

Journal

RSC ADVANCES
Volume 12, Issue 50, Pages 32230-32236

Publisher

ROYAL SOC CHEMISTRY
DOI: 10.1039/d2ra05792a

Keywords

-

Funding

  1. Dongguan Social Development Science and Technology Funds
  2. Guangdong Basic and Applied Basic Research Foundation
  3. Guangdong Province for Science and Technology Innovative Young Talents
  4. [20211800904632]
  5. [2019A1515110978]
  6. [2021B1515140018]
  7. [2021KQNCX097]

Ask authors/readers for more resources

In this study, the quantification of magnesium, copper, manganese, and chromium in aluminum alloy samples was achieved using the femtosecond laser-induced breakdown spectroscopy (fs-LIBS) technique. The experimental parameters were optimized, and background signal preprocessing methods were applied to improve the sensitivity and accuracy of the analysis. The calibration curves and detection limits were established for each element, and significant improvement was observed compared to the results obtained using the fs-LIBS technique.
In this work, magnesium (Mg), copper (Cu), manganese (Mn) and chromium (Cr) in aluminum alloy samples were quantified by femtosecond laser-induced breakdown spectroscopy (fs-LIBS). The different parameters affecting the experimental results, including the laser pulse energy, moving speed of the 2D platform and spectral average number were optimized. The background signal preprocessing methods of median filtering (MF corrected) and Savitzky-Golay filtering (SG corrected) algorithms were used and the effect of the LIBS spectral analysis in the experiment investigated. The calibration curves of Mg, Cu, Mn and Cr elements were established separately and their corresponding detection limits (LODs) were calculated. After background correction, the LODs of Mg, Cu, Mn and Cr elements in MF corrected were 54.52, 11.69, 7.33 and 27.72 ppm, and in SG corrected were 59.15, 17.48, 14.75 and 31.97 ppm. The LODs of these elements in MF corrected and SG corrected have 1.4-5.2 and 1.2-2.5 improvement factors compared to those obtained using the fs-LIBS technique. This work demonstrates that background signal preprocessing methods are very helpful for improving analytical sensitivity and accuracy in quantitative analyses of aluminum alloys.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available