3.8 Proceedings Paper

Simulation framework for reflective PPG signal analysis depending on sensor placement and wavelength

Publisher

IEEE
DOI: 10.1109/BSN56160.2022.9928522

Keywords

photon-tissue interaction; dilated blood vessel; photon packets; signal quality; radial artery; wearable sensor

Funding

  1. Bavarian Academic Forum (BayWISS) Joint Academic Partnership Health
  2. Bavarian State Ministry of Science and the Arts

Ask authors/readers for more resources

This study analyzes the influence of reflective photoplethysmography (PPG) sensor positioning relative to blood vessels. The results show that a symmetrical arrangement of the PPG sensor around the blood vessel yields the maximum AC signal, while incorrect positioning leads to a deterioration in signal quality. Additionally, blood has the most profound effect on signal quality, and the position of the blood vessel also affects the mean penetration depth.
We analyse the influence of reflective photoplethysmography (PPG) sensor positioning relative to blood vessels. A voxel based Monte Carlo simulation framework was developed and validated to simulate photon-tissue interactions. An anatomical model comprising a multi-layer skin description with a blood vessel is presented to simulate PPG sensor positioning at the volar wrist. The simulation framework was validated against standard test cases reported in literature. The blood vessel was considered in regular and dilated states. Simulations were performed with 108 photon packets and repeated five times for each condition, including wavelength, relative position of PPG sensor and vessel, and vessel dilation state. Statistical weights were associated to photon packets to represent absorption and scattering effects. A symmetrical arrangement of the PPG sensor around the blood vessel showed the maximum AC signal. When the PPG sensor was not centrally placed over the vessel, simulated photon weight in systolic and diastolic state deteriorated by >= 5% for both wavelengths. With a position-dependent variation of >= 5% at 660nm and >= 12% at 940nm of light absorption, blood had the most profound effect on signal quality. The mean penetration depth is dependent on the blood vessel position for both wavelengths. Our simulation results demonstrate the susceptibility of reflective PPG measurement to interference and could explain wearable PPG sensor performance variations related to positioning and wavelength.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

3.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available