4.2 Article

Selective nanosensor based on folic acid imprinted nanostructures

Journal

TURKISH JOURNAL OF CHEMISTRY
Volume 46, Issue 4, Pages 1210-1225

Publisher

Tubitak Scientific & Technological Research Council Turkey
DOI: 10.55730/1300-0527.3428

Keywords

Folic acid; nanostructures; MIP; nanobiosensors

Funding

  1. Scientific and Technological Research Council of Turkey [TUBITAK-219S055]

Ask authors/readers for more resources

Folic acid plays a crucial role in metabolism, and deficiencies in folic acid metabolism can lead to various disorders. This study developed a nanosensor for the determination of folic acid in commercially human blood serum, demonstrating a novel, simple, selective, and rapid approach.
Folic acid, which provides the transfer of single carbon atoms in synthesis reactions and metabolic cycles in metabolism, is very important for metabolism. Folic acid also plays an important role in nucleotide synthesis and methylation reactions. There are many disorders caused by defective folic acid metabolism and lack of folic acid. Today, innovative, cost-effective methods are needed to develop folic acid determination methods. The main objective of this study is the development of surface-printed carbon electrodes (SPOE) modified with folic acid imprinted nanostructures (FA-Imp-poly(MPTS-rGO-co-NAT), which will be used for the first time for folic acid determination in commercially human blood serum. For this purpose, the synthesis of nanostructures has been carried out and characterized by FTIR, SEM-EDS, and AFM. Then, a new chemically modified nanosensor was fabricated for the determination of folic acid using folic acid imprinted nanostructures. Differential pulse voltammetry (DPV) and circular voltammetry (CV) methods were used as electrochemical methods in the FA-imprinted-nanosensor studies. Measurements in differential pulse voltammetry were performed at an application speed of 0.005 volts per second in the potential range of -0.4 to 0.6 volts. As a result of the circular voltammetric method, an idea about the surface was obtained with the voltammograms obtained. The detection limit (LOD) of the developed FA-imprinted-nanosensor was 7.54 ng/mL and the determination limit (LOQ) was 25.14 ng/mL. FA analytical (10 and 20 ng/mL) was added to commercial synthetic serum samples by the standard adding method and RSD values of 0.092% and 0.734% were found in the DPV technique and measurements respectively. This manuscript demonstrated a novel, simple, selective, and rapid FA-imprinted-nanosensor for determining the FA in the biological samples.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available